Omron NJ Series User Manual page 101

Machine automation controller, cpu unit built-in ethernet/ip port
Hide thumbs Also See for NJ Series:
Table of Contents

Advertisement

Variable name
Meaning
_EIP2_EtnOnlineSta
Port2 Online
_EIP_TDLinkRunSta
Tag Data Link Com-
munications Status
_EIP1_TDLinkRun-
CIP Communica-
Sta
tions1 Tag Data Link
Communications Sta-
tus
_EIP2_TDLinkRun-
CIP Communica-
Sta
tions2 Tag Data Link
Communications Sta-
tus
_EIP_TDLinkAllRun-
All Tag Data Link
Sta
Communications Sta-
tus
NJ/NX-series CPU Unit Built-in EtherNet/IP Port User's Manual (W506)
3 System-defined Variables Related to the Built-in EtherNet/IP Port
Function
Indicates that the built-in EtherNet/IP
port's communications can be used via
the communications port 2 (that is, the
link is ON, IP address is defined, and
there are no errors.)
TRUE: The built-in EtherNet/IP port's
communications can be used.
FALSE: The built-in EtherNet/IP port's
communications is disabled due to an er-
ror in initial processing, restart process-
ing, or link OFF status.
Note You can use this system-de-
fined variable only for the
NX701 CPU Units and NX102
CPU Units.
NX-series CPU Units: Indicates that at
least one connection is in normal opera-
tion in CIP communications 1.
TRUE: Normal operation
FALSE: Other than the above.
NJ-series CPU Units: Indicates that at
least one connection is in normal opera-
tion.
TRUE: Normal operation
FALSE: Other than the above.
Indicates that at least one connection is
in normal operation in CIP communica-
tions 1.
TRUE: Normal operation
FALSE: Other than the above.
Note You can use this system-de-
fined variable only for NX-ser-
ies CPU Units.
Indicates that at least one connection is
in normal operation in CIP communica-
tions 2.
TRUE: Normal operation
FALSE: Other than the above.
Note You can use this system-de-
fined variable only for the
NX701 CPU Units and NX102
CPU Units.
NX-series CPU Units: Indicates that all
tag data links are communicating in CIP
communications 1.
TRUE: Tag data links are communicating
in all connections as the originator.
FALSE: An error occurred in at least one
connection.
NJ-series CPU Units: Indicates that all
tag data links are communicating.
TRUE: Tag data links are communicating
in all connections as the originator.
FALSE: An error occurred in at least one
connection.
Range of
Data type
values
BOOL
TRUE or
FALSE
BOOL
TRUE or
FALSE
BOOL
TRUE or
FALSE
BOOL
TRUE or
FALSE
BOOL
TRUE or
FALSE
Reference
page 3-52
3
page 3-52
page 3-52
page 3-53
page 3-53
3-23