9 Socket Service
9-5

Socket Service Instructions

You can use the following socket service instructions for socket services.
Refer to the NJ/NX-series Instructions Reference Manual (Cat. No. W502) for information on the sock-
et service instructions.
UDP/TCP
UDP sockets
TCP sockets
Services for both UDP
and TCP sockets
Precautions for Correct Use
You can execute a maximum of 32 socket service instructions (64 for NX102) at the same time.
Perform exclusive control in the user program so that 33 or more socket instructions (65 or
more for NX102) will not be executed at the same time.
9-12
Instruction
SktUDPCreate
Create UDP Socket instruction
SktUDPRcv
UDP Socket Receive instruction
SktUDPSend
UDP Socket Send instruction
SktTCPAccept
Accept TCP Socket instruction
SktTCPConnect
Connect TCP Socket instruction
SktTCPRcv
TCP Socket Receive instruction
SktTCPSend
TCP Socket Send instruction
SktGetTCPStatus
Read TCP Socket Status instruction
SktClose
Close TCP/UDP Socket instruction
SktClearBuf
Clear TCP/UDP Socket Receive Buffer instruction
SktSetOption
Set TCP Socket Option instruction
NJ/NX-series CPU Unit Built-in EtherNet/IP Port User's Manual (W506)
Socket service