8 CIP Message Communications
General
status
code (hex)
02
Resource unavailable
03
Invalid parameter value
04
Path segment error
05
Path destination unknown
06
Partial transfer
07
Connection lost
08
Service not supported
09
Invalid attribute value
0A
Attribute list error
0B
Already in requested
mode/state
0C
Object state conflict
0D
Object already exists
0E
Attribute not settable
0F
Privilege violation
10
Device state conflict
11
Reply data too large
12
Fragmentation of a primi-
tive value
13
Not enough data
14
Attribute not supported
15
Too much data
16
Object does not exist
17
Service fragmentation se-
quence not in progress
18
No stored attribute data
19
Store operation failure
1A
Routing failure (request
packet too large)
1B
Routing failure (response
packet too large)
8-36
Status name
Resources needed for the object to perform the requested service
were unavailable.
See Status Code 20 hex.
The path segment identifier or the segment syntax was not under-
stood by the processing node. Path processing stops when a path
segment error occurs.
The path is referencing an object class, instance, or structure ele-
ment that is not known or is not contained in the processing node.
Path processing stops when a Path Destination Unknown Error oc-
curs.
Only part of the expected data was transferred.
The message connection was lost.
The requested service was not supported or was not defined for this
object class/instance.
Invalid attribute data was detected.
An attribute in the Get_Attribute_List or Set_Attribute_List response
has a non-zero status.
The object is already in the mode/state being requested by the serv-
ice.
The object cannot perform the requested service in its current mode/
state.
The requested instance of object to be created already exists.
A request to modify a non-modifiable attribute was received.
A permission/privilege check failed.
The device's current mode/state prohibits the execution of the re-
quested service.
The data to be transmitted in the response buffer is larger than the
allocated response buffer.
The service specified an operation that is going to fragment a primi-
tive data value, i.e. half a REAL data type.
The requested service did not supply enough data to perform the
specified operation.
The attribute specified in the request is not supported.
The service supplied more data than was expected.
An object that does not exist was specified for the requested serv-
ice.
The fragmentation sequence for this service is not currently active
for this data.
The attribute data of this object was not saved prior to the requested
service.
The attribute data of this object was not saved due to a failure dur-
ing the attempt.
The service request packet was too large for transmission on a net-
work in the path to the destination. The routing device was forced to
abort the service.
The service response packet was too large for transmission on a
network in the path from the destination. The routing device was
forced to abort the service.