Optional Equipment; Re012/E And Re013/E 2-Channel/ 4-Channel Hand-Held Transmitters 304 Mhz; We800/E 304 Mhz Rf Receiver - Bosch ICP-CC408 Installation Manual

Table of Contents

Advertisement

ICP-CC408 | Installation Guide | 20.0
Figure 17: Connections for CP-5 Master
Partitioned Codepad and CP-5 Area
Addressable Codepad
1 = Data
2 = CLK
3 = +12 V
4 = GND
Set the DIP Switches and program these locations for
the two CP-5 Area Addressable (CP500AW)
Codepads to function correctly.
1. Set DIP Switch 1 on the back of the remote
codepad for Area 1 to the ON position.
2. Set DIP Switch 2 on the back of the remote
codepad for Area 2 to the ON position.
3. Select Option 2 in Location 432 (refer to Section
19.3.1 Partitioning Options 1 on page 82).
4. For Output 1, program Location 368 to 6 and
Location 369 to 1 (refer to page 73).
Bosch Security Systems, Inc. | 12/08 | F01U089463-02

Optional Equipment

5 = Master Partitioned
Codepad
6 = Addressable Area
Codepad
Figure 18: Connections for Two CP-5 Area
Addressable Codepads
1 – Data
2 – CLK
3 – +12 V
20.0 Optional Equipment
Bosch Security Systems, Inc., manufactures a number
of accessories that can be used in conjunction with
the ICP-CC408 Control Panel. These optional pieces
of equipment enhance certain features to make the
system extremely flexible.
20.1
RE012/E and RE013/E 2-Channel/
4-Channel Hand-Held Transmitters
304 MHz
These hand-held radio transmitters can be used in
conjunction with the RE005/E 304 MHz RF
Receiver to operate the system remotely. Both hand-
held transmitters can remotely arm and disarm the
system in AWAY Mode or STAY Mode 1 and can
activate remote Panic Alarms. The 4-channel hand-
held transmitter can also operate outputs such as
garage doors, swimming pool pumps, or outside
lights.
20.2

WE800/E 304 MHz RF Receiver

This interface allows the use of up to eight radio User
Codes (9 to 16). This is useful if you want the system
to be radio controlled and you would like to give
your customer total control using a radio hand-held
remote transmitter.