15.17 System Status – Low Battery
Report
352 to 353
Location
Tens digit
Units digit
A Battery Test Failure Report (Contact ID Event
Code 309) is sent to the base station receiver when
the system's battery voltage falls below 11.2 VDC or
when a dynamic battery test detects a low capacity
battery.
The control panel continually monitors the battery
voltage. Refer to Section 4.13 Fault Descriptions on
page 24 for more information. A dynamic battery test
is performed every time the system is armed and
every four hours after the control panel is powered
up.
f Low Battery Reports are not required,
I
program Locations 352 and 353 as 0.
15.18 System Status – Low Battery
Restore Report
354 to 355
Location
Tens digit
Units digit
A Low Battery Restore Report is sent if the backup
battery is restored the next time the system is armed,
or when the next dynamic battery test reports the
battery test is OK.
If Low Battery Restore Reports are not
required, program Locations 354 and 355
as 0.
15.19 System Status – Access Denied
Location
356 to 358
Code Retry Limit
(0 = Unlimited)
Tens Digit
Units Digit
An Access Denied Report (Contact ID Event Code
421) is sent to the base station receiver when the
number of incorrect code attempts equals the
number programmed in Location 356. An Access
Denied Alarm is audible, but you can program the
alarm as silent by selecting Option 8 in Location 425
(refer to Section 18.2 System Options 2 on page 79).
Bosch Security Systems, Inc. | 12/08 | F01U089463-02
System Reporting Information
Location
Default
352
10
Code Retries
353
1
The Code Retries feature restricts the number of
times an invalid User Code can be entered in an
attempt to operate the system. Location 356 sets the
number of incorrect code attempts that causes an
alarm. When the number of incorrect code attempts
equals the number programmed in this location, the
system performs these actions:
Each time the system is armed or disarmed, the Code
Location
Default
Retries counter is reset. You can program the counter
354
10
to a value from 1 to 15. If you want the number of
355
6
incorrect code attempts to be unlimited, program a 0
in Location 356. In this case, the Access Denied
Report is never generated and the system does not
perform the three actions listed above. This function
works when the system is armed or disarmed.

15.20 System Status Reporting Options

Location
0
1
2
4
8
Location
Default
356
6
This location is set by default to report only to
Receiver 1. You can select whether System Status
357
7
Reports are sent to Receiver 1, Receiver 2, or both,
358
12
Receiver 2 only when Receiver 1 fails, or there is no
reporting at all.

15.21 Test Reporting Time

Location
Hour of day (tens digit)
Hour of day (units digit)
Minute of day (tens digit)
Minute of day (units digit)
Test Report (tens digit)
Test Report (units digit)
Repeat interval in days
Restore reports for this event are not
transmitted.
If Access Denied reports are not required,
program Locations 357 and 358 as 0.
Activates the sirens, internal screamers, and
strobes connected to the control panel. Select
Option 8 in Location 425 (refer to Section Section
18.2 System Options 2 on page 79) to change this
alarm to silent.
Shuts down all codepads connected to the
control panel and locks them out for the time
period programmed in Location 410 (refer to
Section 17.8 Codepad Lockout Time on page 77).
Sends an Access Denied Report (Contact ID
Event Code 421) to the base station receiver.
359
No Codepad Alarm Reports allowed
Report to Receiver 1
Report to Receiver 2
Report to both Receiver 1 and Receiver 2
Report to Receiver 2 only if Receiver 1 fails
360 to 366
EN | 67
Location
Default
360
0
361
0
362
0
363
0
364
7
365
1
366
0