ICP-CC408 | Installation Guide | 24.0
Sensor Watch Time
408 to 409
Location
Default
Location 408
Increments of days (tens digit)
Location 409
Increments of days (units digit)
Codepad Lockout Time
Location
410
Default
Location 410
Increments of 10 sec
Siren Run Time
Location
411
Default
Location 411
Increments of 1 min
Siren Sound Rate (Slow <- Sound -> Fast)
412
Location
Default
Auto Arming Pre-Alert Time
413
Location
Default
Location 413
Increments of 5 min
Auto Arming Time
Location
414 to 417
Default
Location 414
Hour of the day – tens digit
Location 415
Hour of the day – units digit
Location 416
Minute of the day – tens digit
Location 417
Minute of the day – units digit
Auto Disarming Time
Location
418 to 421
Default
Location 418
Hour of the day – tens digit
Location 419
Hour of the day – units digit
Location 420
Minute of the day – tens digit
Location 421
Minute of the day – units digit
Kiss-Off Wait Time
Location
422
Default
Location 434
Increments of 500 ms
Reserved
Location
423
System Options 1
Location
424
1
Bosch Security Systems, Inc. smart lockout allowed
2
Horn speaker monitor
4
Strobe indications for radio arm/disarm
8
Allow horn speaker beeps for radio arm/disarm
Bosch Security Systems, Inc. | 12/08 | F01U089463-02
Programming Sheets
System Options 2
Refer to page 76
Location
0 0
Default
1
Codepad Panic to be silent
2
Codepad Fire to be silent
4
Codepad Medical to be silent
8
Access denied (code retries) to be silent
Refer to page 77
System Options 3
0
Location
1
AC fail after 1 hour (disabled = after 2 min)
2
Ignore AC fail
Refer to page 77
4
Pulse count handover allowed
5
8
Handover delay to be sequential
System Options 4
Location
Refer to page 77
Default
7
1
Panel to power up disarmed (if power reset)
2
Arm/disarm tracking on power up
Refer to page 77
4
Internal crystal to keep time
1
8
Night arm station, or RE005/E installed
Consumer Options 1
Location
Refer to page 77
Default
0 0 0 0
1
Test reports only when armed
2
Test report after siren reset
4
Auto arm in STAY Mode 1
8
STAY indicator to display Day Alarm status
Consumer Options 2
Location
Refer to page 77
1
Codepad display extinguishes after 60 sec
0 0 0 0
2
Single button arming allowed (AWAY/STAY Modes
1 and 2)
4
Single button disarming allowed (STAY Modes 1
and 2)
8
Alarm memory reset on disarm
Consumer Options 3
Location
Refer to page 77
1
Codepad fault beeps allowed
3
2
Use digit 3 for Codepad Duress Alarm (instead of
digit 9)
4
Alarms activate sirens and strobe outputs in STAY
Mode 1 and 2
8
Reserved
Radio Input Options
Refer to page 78
Location
Default
1
WE800/E Radio Receiver
2
Latching keyswitch input
3
Momentary keyswitch input
4
Reserved
425
Refer to page 79
0
426
Refer to page 79
427
Refer to page 80
0
428
Refer to page 80
0
429
Refer to page 81
430
Refer to page 81
431
Refer to page 81
0
EN | 103
Need help?
Do you have a question about the ICP-CC408 and is the answer not in the manual?