User Code Priority; Table 50: Priority Levels - Bosch ICP-CC408 Installation Manual

Table of Contents

Advertisement

ICP-CC408 | Installation Guide | 13.0
If you want to remotely operate the system using
hand-held remote transmitters, you can program
User Codes 9 to 16 as remote user codes. Refer to
Section 5.0 Remote Radio Transmitter Operations on page
25 for information on remote operations and adding
and deleting Remote Radio User Codes.
Location
185 to 264
User Code 1
Priority Level
User Code 2
Priority Level
User Code 3
Priority Level
User Code 4
Priority Level
User Code 5
Priority Level
User Code6
Priority Level
User Code 7
Priority Level
User Code 8
Priority Level
User Code 9
Priority Level
User Code 10
Priority Level
User Code 11
Priority Level
User Code 12
Priority Level
User Code 13
Priority Level
User Code 14
Priority Level
User Code 15
Priority Level
User Code 16
Priority Level
Bosch Security Systems, Inc. | 12/08 | F01U089463-02
Access Codes
Location
Default
185
2
186
5
187
8
188
0
189
10
190 to 193
15
194
2
195 to 198
15
199
2
200 to 203
15
204
2
205 to 208
15
209
2
210 to 213
15
214
2
215 to 218
15
219
2
220
0
221 to 223
15
224
3
225 to 228
15
229
2
230 to 233
15
234
2
235 to 238
15
239
2
240 to 243
15
244
2
245 to 248
15
249
2
250 to 253
15
254
2
255 to 258
15
259
2
260 to 263
15
264
2
13.3

User Code Priority

The installer can assign one of ten different priority
levels to a User Code. Each priority level allows or
restricts a user from performing specific functions.

Table 50: Priority Levels

Priority
Description
Level
0
Arm/disarm
1
Arm only
2
Arm/disarm and Open/Close Reports
3
Arm only and Close Report
4
Arm/disarm and code to isolate
6
Arm/disarm, code to isolate, and Open/Close
Reports
8
Arm/disarm and Master Code functions
10
Arm/disarm, Master Code functions, and
Open/Close Reports
12
Arm/disarm, Master Code functions, and code
to isolate
14
Arm/disarm, Master Code functions, code to
isolate, and Open/Close Reports
Arm/Disarm
The user can arm and disarm the system. A Closing
Report is sent only after a previous code with the
ability to send an Opening Report disarms the
system.
Arm Only
The user can arm the system but cannot disarm the
system. A Closing Report is sent only after a previous
code with the ability to send an Opening Report
disarms the system.
Open/Close Reports
Open and Close reports are sent to the monitoring
station when the user disarms and arms the system,
but only if Open/Close Reports is enabled in
Locations 333 and 334 (refer to Section 15.6
Open/Close Reports on page 65).
Code To Isolate
If one or more User Codes has this option included,
the method of standard isolating is disabled and only
a User Code with this option in its priority level can
isolate zones before arming the system using the
Code to Isolate method. Refer to Section 4.11 Isolating
Zones on page 23 for more information.
When priority level 4, 6, 12, or 14
assigned to any User Codes, the
Standard Isolating method no longer
operates. Only User Codes with a priority
level of 4, 6, 12, or 14 can isolate zones
using the Code to Isolate method.
EN | 55

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ICP-CC408 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents

Save PDF