ICP-CC408 | Installation Guide | 1.0
1.0 Introduction
Congratulations on selecting the ICP-CC408 Control
Panel for your installation. Take the time to read
through this guide and familiarize yourself with the
outstanding operating and installation features of this
system so you can get the most from your unit.
In all aspects of planning, engineering, styling,
operation, convenience, and adaptability, we try to
anticipate your every possible requirement.
Programming simplicity and speed are major
considerations; we believe that our objectives are
more than satisfied.
This installation guide explains all aspects of
programming the ICP-CC408 Control Panel from
factory default to final commissioning. All system
parameters and options are detailed, but suitability is
left to the individual. Each control panel can be
tailored to meet your requirements quickly and
easily. The programming simplicity makes your
installation quick, accurate, and rewarding.
As ICP-CC408 Control Panels continue to improve
over the years, they become very powerful. We have
addressed the needs of some early first-time users
who have advanced to true "power users," while
maintaining simplicity of the product and the
installation guide.
1.1
ICP-CC408 Features
The ICP-CC408 Security System uses the latest in
microprocessor technology to provide you with
useful features, and superior reliability and
performance.
The control panel provides these features:
•
Eight programmable User Codes (1 to 8)
•
Eight variable User Codes (radio
remote/programmable User Codes (9 to 16))
•
Eight programmable Burglary Zones
•
Partitionable to two separate areas
•
Dual reporting
•
On-board Line Fault Module
•
Telco arming/disarming Sequence
•
Automatic arming and disarming
•
Codepad Duress, Panic, Fire, and Medical
Alarms
•
STAY Mode and AWAY Mode operation
•
Upload/download programmable
•
Dynamic battery testing
•
Entry and Exit Warning beeper
•
Remote arming
•
Answering machine bypass
Bosch Security Systems, Inc. | 12/08 | F01U089463-02
Introduction
•
AC fail and system fault indicators
•
Monitored Siren Output
•
Strobe Output
•
Relay Output
•
Separate Fire Alarm sound
•
EDMSAT – Satellite Siren-compatible
•
Zone lockout
•
Sensor watch
•
Day Alarm
•
Walk Test Mode
•
Delayed reporting
•
40 events in non-volatile memory
1.2
Quick Start
The following steps allow you to use the ICP-CC408
Control Panel with factory default values. The default
values allow the control panel to communicate in the
Contact ID format. If you are not familiar with
programming ICP-CC408 control panels, read the
information in Section
before starting the installation.
1. Connect the backup battery.
2. After all wiring is complete, connect the AC plug
pack to the control panel.
Both the MAINS and AWAY indicators are lit.
The MAINS indicator lights to indicate the AC
MAINS supply is connected.
The AWAY indicator lights to signify the system
is armed in AWAY Mode.
If any 24-Hour zones are unsealed when you
power up the system, the Siren, Strobe, and Bell
Outputs are activated into alarm and the
corresponding zone indicator flashes.
3. Enter the default Master Code (2580) and press
[AWAY] to disarm the system and to reset any
alarm that occurred when you powered up the
system.
The AWAY indicator is extinguished to signify
that the system is disarmed.
If any zone indicator is flashing, an alarm
occurred in that zone.
If a zone indicator is lit constantly, the zone is
unsealed.
4. Enter the default Installer Code (1234) and press
[AWAY].
Two beeps sound and the STAY and AWAY
indicators flash simultaneously to indicate that
you entered Installer's Programming Mode.
When entering Installer's Programming Mode,
you are automatically positioned at Location 000,
the first digit of the Primary Telephone Number
for Receiver 1.