Teledyne T3EL15030 P Series User Manual page 59

Programmable dc electronic load
Table of Contents

Advertisement

Figure 2-48 The waveform display in CC mode
Operating Steps
1. Set Time
The time set range is 4 s - 80 h in all modes.
Tip
When the time that you set is greater than 120s, it will be
automatically displayed in minutes. When greater than 120 min, it will
be automatically displayed in hours.
2. Set Data
Menu items under "Data" include I, U, R, and P.
3. Pause and Start
When the "Pause" key is pressed, the load will suspend the data
collection and graphing of the waveform. When the "Start" key is
pressed, the load will continue to graph waveform. These operations
govern graphing only. The active state of the load is still being
governed independently by the current settings, list, or program
running.
4. Print
After you insert the USB storage device, press "Print" to capture the
screen or images and save them in ".BMP" format to the USB storage
device.
5. Record
After you insert the USB storage device, press the "Record" key to save
56