9.2 STARTUP WIZARD for Asynchronous motor

The STARTUP WIZARD is a guided procedure used for quick start-up of the drive that helps to set the main
parameters.
It consists of a series of questions, relating to the various sequences for entering and calculating the parameters
necessary for correct drive and lift application operation. The order of these sequences is as follows:
Setting communication
Setting encoder parameters (Control type = ASY SSC o ASY FOC)
Setting motor parameters
Setting mechanical system data
Setting the maximum speed reference and maximum system speed
Autotune with motor at stand-still
Saving parameters
The format of the function selection page is as follows:
01 STARTUP WIZARD
02 OPTIMIZATION WIZARD
03 TROUBLESHOOTING
04 DRIVE
Pressing the E key, the function to be programmed is accessed.
Press the ▼ (Down) key to move to the next function skipping the current function.
Press the ▲ (Up) key to return to the previous function.
To terminate the sequence of functions and return to the menu, press the ESC key.
At the end of the sequence, once the parameters have been saved, if commissioning is successful, the main menu will
return.
64
STARTUP WIZARD
E
Set comm mode?
E=Yes
ADL500 • Quick installation guide - Specifications and connection
Down=Next
See step 1
See step 2
See step 3
See step 4
See step 5
See step 6
See step 7