8.2 Navigating with the optional keypad

8.2.1 Scanning of the first and second level menu

First level
01
STARTUP WIZARD
02
OPTIMIZ. WIZARD
03
TROUBLESHOOTING
04
DRIVE
First level
01
STARTUP WIZARD
02
OPTIMIZ. WIZARD
03
TROUBLESHOOTING
04
DRIVE

8.2.2 Display of a parameter

04
DRIVE
05
LIFT
07
COMMUNICATION
08
MOTOR DATA
(1) Reference to the menu where the parameter is to be found, in this case menu MOTOR DATA (02/30)
(2) Description of the parameter (Rated voltage)
(3) Depends on the type of parameter:
Numeric parameter: displays the numeric value of the parameter, in the format required, and unit of measurement.
Binary selection: the parameter may assume only 2 states, indicated as On - Off or 0 - 1.
LINK type parameter: displays the description of the parameter set from the selection list.
ENUM type parameter: displays the description of the selection
Command: displays the method of execution of the command
(4) Parameter number
(5) In this position, the following may be displayed:
Numeric parameter: displays the default, minimum and maximum values of the parameter. These values are dis-
played in sequence pressing the ► key.
LINK type parameter: displays the number (PAR) of the parameter set.
ENUM type parameter: displays the numeric value corresponding to the current selection.
Command: in the case of an error in the command, indicates that ESC must be pressed to terminate the com-
mand.
Messages and error conditions:
Param read only
Drive enabled
Input value too high
Input value too low
Out of range
52
13
FUNCTIONS
01
STARTUP WIZARD
02
OPTIMIZ. WIZARD
03
TROUBLESHOOTING
01
STARTUP WIZARD
02
OPTIMIZ. WIZARD
03
TROUBLESHOOTING
04
DRIVE
Second level
04.01
DRIVE MONITOR
04.02
DRIVE INFO
04.03
DRIVE CONFIG
04.04
ALARM CONFIG
j
02 /30
Rated voltage
k
Def:
400
l
attempt to modify a read-only parameter
attempt to modify a non-modifiable parameter with the drive enabled
the value entered too high
the value entered too low
attempt to insert a value outside the min. and max. limits
ADL500 • Quick installation guide - Specifications and connection
m
PAR:
2000
400