8.2.8 Configuration of the display

8.2.8.1 Language selection

Menu CONFIG DRIVE, parameter 04.19 Language select, PAR: 578, default=English.
This is used to set one of the languages available: English, Italian, French, German, Spanish and Turkish.
To set a language other than English or Italian (pre-installed on the drive) contact the technical service centre.
04.01
04.02
04.03
04.04
12 /18
Language select
Italian
Value:
Press E to confirm the modification or ESC to cancel.

8.2.8.2 Access level selection

Menu CONFIG DRIVE, parameter 04.03 Access mode, PAR: 554.
Enables two methods of access to be configured:
Readonly
Easy
Intermediate
Expert
Service
04.01
04.02
04.03
04.04
04 /18
Access level
Easy
Value:

8.2.9 Startup display

Menu CONFIG DRIVE, parameter Startup display, PAR: 574.
This is used to set the parameter that will be displayed automatically at drive power-on.
Entering the value -1 (default), the function is disabled and the main menu is displayed at power-on.

8.2.10 Back-lighting of the display

Menu CONFIG DRIVE, parameter Display backlight, PAR: 576. Sets lighting of the display:
On
Off
56
DRIVE MONITOR

DRIVE INFO
DRIVE CONFIG
ALARM CONFIG
PAR:
578
1
a read-only level, where a limited number of parameters are displayed.
this level allows the parameters to be displayed and modified for basic commissioning, in V/f
control and without tuning.
(default) this level allows the parameters to be displayed and changed for complete commission-
ing and basic optimisation.
this level is for displaying and changing parameters for advanced optimisation.
Reserved for Gefran Service.
DRIVE MONITOR

DRIVE INFO
DRIVE CONFIG
ALARM CONFIG
PAR:
554
1
the light of the display always stays on.
(default) the light switches off approx. 3 minutes after the last key is pressed.
ADL500 • Quick installation guide - Specifications and connection
12 /18
PAR:
Language select
x5
English
Value:
0
04 /18
PAR:
Access level
x3
Intermediate
Value:
2
12 /18
578
Language select
E
English
Value:
0
04 /18
554
Access level
E
Intermediate
Value:
2
PAR:
578
PAR:
554