Error Display Interface - gefran RADIUS Installation & Operation Manual

Log light data logger for plant monitoring
Table of Contents

Advertisement

3.4
Error Display interface
When inverter error occurs, RADIUS Log Light automatically switch to Error display interface and make a
sound continue for about 10 seconds.
After inverter error occurs, RADIUS Log Light display error code in screen. Meanings of error codes are shown
in the following table.
Fault code
0~22
23
24
25
26
27
28
29
30
31
Also the corresponding error messages will display in inverter's screen.
Radius Log Light
Error:100
Error:122
Inverter display
Meanings
Error: 100+x
eg: Error:100 or Error:122
Auto Test Failed
Auto test interrupted
No AC Connection
Grid haven't connected
PV Isolation Low
Impedance between PV positive/negative and
ground are too low
Residual I High
Residual current too high
Output High DCI
High DC value in AC output
PV Voltage High
PV voltage input too high
AC V Outrange
AC voltage out of range
AC F Outrange
AC frequence out of range
Module Hot
Inverter temperature high
Table 3.2 Error codes display in RADIUS Log Light
Auto Test Failed
......
Fig 3.6 Error message display
13