8.2 Navigating with the optional keypad

8.2.1 Scanning of the first and second level menus

First level
01 MONITOR
02 DRIVE INFO
03 STARTUP WIZARD
04 DRIVE CONFIG
05 LIFT
First level
01 MONITOR
02 DRIVE INFO
03 STARTUP WIZARD
04 DRIVE CONFIG
05 LIFT
Note!
This example is only visible in Expert mode.

8.2.2 Display of a parameter

j
14 MOTOR DATA
k
01/26
l
Rated voltage
m
Def:
400
(1) Reference to the menu where the parameter is to be found (in this case menu 14 - MOTOR DATA)
(2) Position of the parameter in the menu structure (01)
(3) Description of the parameter (Rated voltage)
(4) Depends on the type of parameter:
Numeric parameter: displays the numeric value of the parameter, in the format required, and unit of measurement.
Binary selection: the parameter may assume only 2 states, indicated as On - Off or 0 - 1.
LINK type parameter: displays the description of the parameter set from the selection list.
ENUM type parameter: displays the description of the selection
Command: displays the method of execution of the command
(5) Parameter number
(6) In this position, the following may be displayed:
Numeric parameter: displays the default, minimum and maximum values of the parameter. These values are dis-
played in sequence pressing the ► key.
LINK type parameter: displays the number (PAR) of the parameter set.
ENUM type parameter: displays the numeric value corresponding to the current selection.
Command: in the case of an error in the command, indicates that ESC must be pressed to terminate the com-
mand.
Messages and error conditions:
Param read only
Password active
Drive enabled
Input value too high
Input value too low
Out of range
23 ALARM LOG
01 MONITOR
02 DRIVE INFO
03 STARTUP WIZARD
04 DRIVE CONFIG
01 MONITOR
02 DRIVE INFO
03 STARTUP WIZARD
04 DRIVE CONFIG
05 LIFT
Second level
05.1 SPEED'
05.2 RAMPS
05.3 LIFT SEQUENCES
05.4 MECHANICAL DATA
05.5 DISTANCE
PAR: 2000
o
400
V
attempt to modify a read-only parameter
the parameter protection password is active
attempt to modify a non-modifiable parameter with the drive enabled
the value entered too high
the value entered too low
attempt to insert a value outside the min. and max. limits