(2) Setting parameters of the wave output function

Set the parameters of the wave output function in "Create Wave Output Data" of GX Works2. Before the
parameter setting, create the wave data.
1.
Start "Create Wave Output Data".
[Tool]
[Create Wave Output Data]
2.
Select "Module Type" according to the module used.
L60DA4
L60DAVL8, L60DAIL8
3.
Set the parameters of the wave output function in "Wave output data setting".
Set parameters of the
wave output function.
Item
Wave pattern No.
Output setting during wave output
stop
[Intelligent Function Module Tool]
Module
Description
Up to three patterns can be specified at a time from registered wave
patterns. When specifying multiple wave patterns, set the pattern No. as
follows.
• When No. 1 and No. 2 are used: 1, 2
• When No. 1, No. 5, and No. 10 are used:
• When No. 1 to No. 3 are used: 1-3
Set the analog output during the wave output stop.
[Analog Module]
"Module Type"
Q64DAH/L60DA4
L60DAVL8/L60DAIL8
1 to 10
• 0: 0V/mA (default value)
• 1: Offset value
• 2: Setting value during stop
CHAPTER 8 FUNCTIONS
Setting range