10.2
When Using the Module in a Standard System
Configuration
This section shows a program example where the following system configuration and conditions apply.
(1) System configuration
The following shows a system configuration example.
CPU module (L26CPU-BT)
Power supply module
(L61P)
(2) Programming condition
Set CH1 and CH2 of the D/A converter module to D/A conversion enable, and then write the digital values.
If a digital value write error occurs, an error code is displayed in BCD.
Configure the scaling setting in CH1 only, and configure the warning output function in CH2 only.
154
X/Y00
X/Y10
X/Y30
X/Y40
X/Y50
to
to
to
to
to
X/Y0F
X/Y2F
X/Y3F
X/Y4F
X/Y8F
D/A converter module (L60DA4)
Input module (LX40C6)
Output module (LY42NT1P)
END cover (L6EC)