(25)Step action wave output request (Un\G1072)
This area is for setting whether to start or end the wave output step action function for all channels in a batch.
This area can be set only in the wave output mode.
For details on the wave output step action function, refer to the following.
• Wave output step action function (
Step action wave output request
• When the setting value is changed OFF (0)  ON (1), the wave output status of all the channels set to D/A
conversion enable becomes to Wave output step action and the wave output step action function becomes
valid. Wave output step action (3) is stored in CH Wave output status monitor (Un\G1100 to Un\G1107).
• When the setting value is changed ON (1)  OFF (0), the wave output status of all the channels becomes to
Wave output stop and the wave output step action function ends.
• Even though the setting value is changed in the mode other than the wave output mode, the change is not
applied.
• In the channel where a value out of the above setting range is set, an error occurs. The error code (360) is
stored in Latest error code (Un\G19), Error flag (XF) turns on, and the ERR. LED turns on. The current wave
output status continues.
(a) Default value
OFF (0) is set.
Page 126, Section 8.8.4)
OFF
ON
Common
Setting value
0
1
APPX
A
205