Mitsubishi Electric MELSEC L Series User Manual page 34

Digital-analog converter module
Hide thumbs Also See for MELSEC L Series:
Table of Contents

Advertisement

Address
Address
(decimal)
(hexadecimal)
158
9EH
159
9FH
160 to 199
A0H to C7H
200
C8H
201
C9H
202
CAH
203
CBH
204
CCH
205
CDH
206
CEH
207
CFH
208
D0H
209
D1H
210
D2H
211
D3H
212
D4H
213
D5H
214
D6H
215
D7H
216
D8H
217
D9H
218
DAH
219
DBH
220
DCH
221
DEH
222
DFH
223
E0H
224
E1H
225
E2H
226
E3H
32
Name
L60DA4
Mode switching setting
System area
Pass data classification
System area
setting
System area
CH1 Industrial shipment
CH1 Industrial shipment
settings offset value
settings offset value
CH1 Industrial shipment
CH1 Industrial shipment
settings gain value
settings gain value
CH2 Industrial shipment
CH2 Industrial shipment
settings offset value
settings offset value
CH2 Industrial shipment
CH2 Industrial shipment
settings gain value
settings gain value
CH3 Industrial shipment
CH3 Industrial shipment
settings offset value
settings offset value
CH3 Industrial shipment
CH3 Industrial shipment
settings gain value
settings gain value
CH4 Industrial shipment
CH4 Industrial shipment
settings offset value
settings offset value
CH4 Industrial shipment
CH4 Industrial shipment
settings gain value
settings gain value
CH1 User range settings
CH5 Industrial shipment
offset value
settings offset value
CH1 User range settings
CH5 Industrial shipment
gain value
settings gain value
CH2 User range settings
CH6 Industrial shipment
offset value
settings offset value
CH2 User range settings
CH6 Industrial shipment
gain value
settings gain value
CH3 User range settings
CH7 Industrial shipment
offset value
settings offset value
CH3 User range settings
CH7 Industrial shipment
gain value
settings gain value
CH4 User range settings
CH8 Industrial shipment
offset value
settings offset value
CH4 User range settings
CH8 Industrial shipment
gain value
settings gain value
CH1 User range settings
System area
offset value
CH1 User range settings
System area
gain value
CH2 User range settings
System area
offset value
CH2 User range settings
System area
gain value
CH3 User range settings
System area
offset value
CH3 User range settings
System area
gain value
CH4 User range settings
System area
offset value
CH4 User range settings
System area
gain value
CH5 User range settings
System area
offset value
Default
L60DAVL8, L60DAIL8
turning on and off
*1
*2
Read/Write
Operating condition
setting request (Y9)
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
0
R/W
Item enabled by

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec l60da4Melsec l60davl8Melsec l60dail8

Table of Contents