(c) Switching the mode by Mode switching setting (Un\G158, Un\G159) and Operating
condition setting request (Y9)
Normal output mode initial setting
Switches to the Offset/gain setting mode
Switches to the normal output mode
(d) Switching the mode by using the switch setting
The program other than the common program is not required.
Configure the switch setting, and reset the CPU module or turn off and on the power to switch the mode.
66
Setting programs for other initial setting items
Common program
D/A conversion enable/disable setting
Turns on Operating condition setting
request (Y39).]
Sets 4144
to Mode switching setting
H
(U3\G158).
Sets 964
to Mode switching setting
H
(U3\G159).
Turns on Operating condition setting
request (Y39).
Sets 964
to Mode switching setting
H
(U3\G158).
Sets 4144
to Mode switching setting
H
(U3\G159).
Turns off Operating condition setting
request (Y39).