Smart Array PCIe plug-in controller
◦
Controller backup power cable
•
Compatible controller cable option
•
T-15 Torx screwdriver
•
If you are installing a Smart Array P-class Gen10 controller, an energy pack option is required.
Before you perform this procedure, perform the following steps:
1. Back up data on the system.
2. Close all applications.
3. Update the server firmware if it is not the latest revision.
4. Do one of the following:
•
If the new Smart Array is the new boot device, install the device drivers.
•
If the new Smart Array is not the new boot device, go to the next step.
5. Ensure that users are logged off and that all tasks are completed on the server.
Procedure
1.
Observe the following alerts:
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system
components to cool before touching them.
CAUTION: To prevent damage to electrical components, properly ground the server before beginning any
installation procedure. Improper grounding can cause electrostatic discharge.
2.
Back up all server data.
3.
If installed, remove the front bezel.
4.
Power down the server.
5.
Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
6.
Disconnect all peripheral cables from the server.
7.
Do one of the following:
Extend the server from the rack.
•
•
Remove the server from the rack.
8.
Remove the access panel.
Hardware options installation