The DIMM slots are structured to ensure proper installation. If you try to insert a DIMM but it does not fit easily
into the slot, you might have positioned it incorrectly. Reverse the orientation of the DIMM and insert it again.
9.
Install the access panel.
10. Install the server into the rack.
11. Connect all peripheral cables to the server.
12. Connect each power cord to the server.
13. Connect each power cord to the power source.
14. Power up the server.
15. If removed, install the bezel.
The installation is complete.
After installing the DIMMs, use the System Utilities > System Configuration > BIOS/Platform Configuration (RBSU) >
Memory Options to configure the memory settings.

Drive options

Hot-plug drive guidelines

When adding drives to the server, observe the following general guidelines:
The system automatically sets all device numbers.
If only one drive is used, install it in the bay with the lowest device number.
Drives should be the same capacity to provide the greatest storage space efficiency when drives are grouped together
into the same drive array.

Drive support information

Depending on the drive cage option installed, the server supports the following drive types:
Hot-plug LFF SATA or SAS drives
Hot-plug SFF SATA or SAS drives
The embedded HPE Smart Array S100i SR Gen10 Controller supports SATA drive installation. For SAS support, install a
Smart Array Gen10 type-a or type-p controller option.

Installing a hot-plug SAS or SATA drive

Procedure
1. If installed, remove the front bezel.
2. Remove the drive blank.
3. Prepare the drive.
SFF drive