1.8.5 Lock LED (Attendant Control Panel)
LOCK LED
Thighrest, Calfrest and Bed Extension Lock LED
Backrest Lock LED
Bed Height, Lateral Tilt, Trendelenburg and Antitrende-
lenburg Tilt Lock LED
Foot Control Lock LED
1.9 Definitions
Basic Bed Configuration
Bed Weight
Clearance of Undercarriage
Duty Cycle
Ergoframe
Maximum Patient Weight
Safe Working Load
Siderail Height
Standard Bed Position
Adult
Maximum Mass of Mobile Hospi-
tal Bed
16
VISUAL
SIGNALISATION
lit
locked
locked
locked
locked
The pricelist model configuration, not including a mattress.
The value depends on the product configuration, accessories or customer adjustments.
The height from the floor to the lowest point of the undercarriage between the castors, for
the manipulation of accessories under a braked bed in the standard position.
Cycle of operation of the motor: time of activity/time of rest.
Ergoframe is the kinematic system of Mattress support platform Adjustment whose effect is
the elimination of pressure on the patient´s abdomen and pelvic area and frictional forces
on the patient's back and legs.
Maximum Patient Weight depends on the application environment according to IEC 60601-
2-52. For application environment 1 (intensive/critical care) and 2 (acute care) reduce Safe
working Load by 65 kg. For application environment 3 (long-term care) and 5 (ambulatory
care) reduce Safe working Load by 35 kg.
The highest allowable load on the bed.
The Safe Working Load is the sum of:
– the patient
– the mattress
– the accessories of the medical bed (only if they are supported by the support system of
the medical bed) and
– the load supported by those accessories (excluding patient weight).
The height of the upper crossbar or the edges of the siderails (not the highest point of the
siderail controls) from the patient surface.
- The height of the patient surface with regard to the floor is 400 mm.
- The mattress support platform, including the individual parts, has to be in a horizontal
position (0°).
- The siderails are always locked in the upper position.
- The basic position of the integrated extension.
Patient having a physical size equal to or more than 146 cm, a mass equal to or more than
40 kg and a body mass index (BMI) equal to or more than 17 (according to IEC 60601-2-
52).
Sum of Maximum Empty Bed Mass and Safe Working Load.
flashing:
0,6s lit / 0,6s not lit
lock error
keyboard error
lock error
keyboard error
lock error
keyboard error
lock error
keyboard error
not lit
motion blocked
unlocked
motion blocked
unlocked
motion blocked
unlocked
motion blocked
unlocked
D9U001MCX-0101_03
Need help?
Do you have a question about the Multicare X and is the answer not in the manual?
Questions and answers