ADM1060
TABLE 38. LIST OF REGISTERS FOR THE PROGRAMMABLE DRIVER OUTPUTS
Hex
Table
Name
Address
0 D
39
P1PDOCFG
1 D
39
P2PDOCFG
2 D
39
P3PDOCFG
3 D
39
P4PDOCFG
4 D
39
P5PDOCFG
5 D
39
P6PDOCFG
6 D
39
P7PDOCFG
7 D
39
P8PDOCFG
8 D
39
P9PDOCFG
TABLE 39. REGISTER 0DH,1DH,2DH,3DH,4DH,5DH,6DH,7DH,8DH
Bit
Name
7
Reserved
6-4
CFG6-CFG4
3-0
CFG3-CFG0
PRELIMINARY TECHNICAL DATA
Power On Value
R/W
Description
N/A
Cannot be used
R / W
Control the logical state of the PDO. These three bits deter
mine what effect, if any, the logical input to the PDO has on its output
CFG6
0
0
0
0
1
R / W
CFG3
0
0
0
0
0
0
1
1
1
1
1
1
Default
Description
00h
Selects the format of the PDO1 output (open drain, open
drain with internal pull-up, charge pumped etc.)
00h
Selects the format of the PDO2 output (open drain, open
drain with internal pull-up, charge pumped etc.)
00h
Selects the format of the PDO3 output (open drain, open
drain with internal pull-up, charge pumped etc.)
00h
Selects the format of the PDO4 output (open drain, open
drain with internal pull-up, charge pumped etc.)
00h
Selects the format of the PDO5 output (open drain, open
drain with internal pull-up etc.).
output is not available on this driver
00h
Selects the format of the PDO6 output (open drain, open
drain with internal pull-up etc.).
output is not available on this driver
00h
Selects the format of the PDO7 output (open drain, open
drain with internal pull-up etc.).
output is not available on this driver
00h
Selects the format of the PDO8 output (open drain, open
drain with internal pull-up etc.).
output is not available on this driver
00h
Selects the format of the PDO9 output (open drain, open
drain with internal pull-up etc.).
output is not available on this driver
CFG5
CFG4
PDO
0
0
0
0
1
PLB_OUT
1
0
0
1
1
1
X
X
M C L K
CFG2
CFG1
CFG0
0
0
X
0
1
X
1
0
0
1
0
1
1
1
0
1
1
1
0
0
0
0
0
1
0
1
0
0
1
1
1
1
0
1
1
1
–30–
ADM1060 OUTPUTS
Note: Charge Pumped
Note: Charge Pumped
Note: Charge Pumped
Note: Charge Pumped
Note: Charge Pumped
PnPDOCFG (POWER- ON DEFAULT 00H)
State
Disabled, with weak pull-down
Enabled, follows PLB Logic Output
Enable SMBus Data, Drive Low
Enable SMBus Data, Drive High
Enable MCLK out onto pin
Pull-Up
Supply
none
V C P
V P 1
V P 1
V P 2
V P 2
V P 3
V P 3
V P 4
V P 4
VDD
VDD
Pull-Up
Strength
N/A
(1/fC)
Low
High
Low
High
Low
High
Low
High
Low
High