Error
Error
Code
Category Title
0001
2
Backup Error
0002
2
USB Drive Backup Error
0003
2
Restore Error
0004
2
USB Drive Restore Error
0005
2
USB Drive Write Error
0006
1
Could Not Import Logo
0007
4
Missing Report Template
0008
4
Corrupt Report Template
0009
2
Instrument Memory Error
0010
6
Instrument Memory Error
0011
4
I2C Bus Error
0012
4
SPI Bus Error
0013
4
Checksum Error
Vision G2 Testers User Guide—74-108-800 Rev. H—12 June 2019
Message
Corrupted data encounterd during backup.
Contact Tech Support.
Error accessing the protocol backup file on the
USB drive. Make sure the USB drive has
enough space or try a different USB drive.
Error restoring the protocols from a protocol
backup file. Data in the instrument memory
might be corrupted. Contact Tech Support.
Error accessing the protocol backup file on the
USB drive. The protocol backup file on the
USB drive might be missing or corrupted.
Error occurred while writing data to the USB
drive. Make sure the USB drive has enough
space or try a different USB drive.
Make sure the logo.jpg file being imported has
the correct format as described in the User
Guide.
Report template missing. Contact Tech
Support.
Report template corrupted. Contact Tech
Support.
Error occurred while accessing instrument
memory. Contact Tech Support.
I2C Bus Error detected. Restart the
instrument. If the problem persists, contact
Tech Support.
SPI Bus Error detected. Restart the
instrument. If the problem persists, contact
Tech Support.
Error occurred while calculating the protocols
checksum. Contact Tech Support.
Appendix A: Errors
Fault
Cannot open one of the protocols on the monument
board when backing up the protocols.
Cannot read or write the protocols backup file from
the USB flash drive when restoring protocols from
backup.
When restoring protocols from a backup, the
checksum of the backup file was checked one more
time at the end of the restore, and it failed. The
protocol data that was copied to the monument
board memory might be corrupted.
Corrupted protocols backup file or the backup file
contains protocols of an unknown version.
Corrupted protocols backup file or the backup file
contains protocols of an unknown version.
Information could not be sent to USB flash drive.
Logo.jpg does not meet system requirements.
Printing templates data is not found in main board
memory. Could be that memory went bad, or cannot
communicate with memory or that data was not
written there during the firmware update, which
means corrupted firmware update image.
Corrupted or invalid data in the printing templates
memory.
Error Reading or Writing information to the
instrument memory located on the monument board.
Error Reading data from the instrument memory or
corrupted data in the instrument memory.
The system detected I2C bus error.
The system detected SPI bus error.
SPI bus error was detected when reading printing
templates from memory during printing.
System is unable to caclulate a checksum for the
protocols.
Check the Following
1. Try a new USB drive.
2. Try a new copy of the backup file.
3. Contact Technical Support if problem persists.
1. Try a new USB drive.
2. Try a new copy of the backup file.
3. Contact Technical Support if problem persists.
1. Try a new USB drive.
2. Try a new copy of the backup file.
3. Contact Technical Support if problem persists.
1. Try a new USB drive.
2. Try a new copy of the backup file.
3. Contact Technical Support if problem persists.
1. Unsupported USB flash drive
2. Monument board failure
3. Main board failure
Logo.jpg requirements in User Guide
1. Bad image file for firmware update
2. Main board failure
1. Bad image file for firmware update
2. Main board failure
1. Normal after a firmware update - should not
persist after first reboot
2. Monument board failure
3. Main board failure
Contact Technical Support
1. Monument board failure
2. Main board failure
3. Display failure
Main board failure
1. Monument board failure
2. Main board failure or corrupted memory or
unknown version of protocol data