12. If internal cables are required for the expansion board or storage controller, connect the cables.
13. Install the PCIe riser into the system board.
14. Install the midplane interposer on the system board module.
15. Install the system board module access panel.
16. Install the system board module into the chassis.
17. Connect all peripheral cables to the server.
18. Power up the server.
19. Configure the new storage controller.
For more information, see the user guide for your controller series on the Hewlett Packard Enterprise website
(http://www.hpe.com/info/smartstorage-docs).
The installation is complete.
More information
Remove the system board module from the chassis
Remove the system board module access panel
Remove the midplane interposer
Installing a PCIe riser
Remove a PCIe riser
Install the midplane interposer
Install the system board module access panel
Install the system board module into the chassis

GPU options

The server supports a maximum of 4 SXM4 GPUs in the SXM GPU tray option, or 4 double-width PCIe GPUs or 8 single-
width PCIe GPUs in the PCIe GPU tray option per system board module. The GPU slots are mapped in 1:1 GPU to PCIe
riser board ratio.

Installing a GPU tray

Prerequisites
Before installing this option, be sure that you have the following:
The components included with the hardware option kit
Four 12 V power supplies installed in the chassis, if installing a PCIe GPU tray
Four 54 V power supplies and two 12 V power supplies installed in the chassis, if installing an SXM4 GPU tray
Hardware options installation
66