Item
1
2
3
4
5
Power supply LED
Status
Solid green
Flashing green (0.5 Hz)
Flashing green (2 Hz)
Solid amber
Off
Fan module numbering
The system supports 15 fan modules. If the system has one fan lesser than the recommended (15) number during boot,
the system will boot in the Nonredundant Mode. If the missing fan is installed, the system will begin functioning in
Redundant Mode. If more than one fan is missing during power up, the user will be allowed to boot, but will be using an
unsupported configuration.
Description
x8 Slim SAS NVMe/SATA 6GB/s port
Pump-cold plate signal connector for processor
Storage controller backup power connector
Slot 10 PCIe4 ×16 (16, 8, 4, 2, 1)
Slim SAS x4 port for front panel LEDs
Description
Power supply is on and is operating normally.
12 V standby power present (Power supply off)
Power supply is in Smart redundant state or offline mode.
12 V fault caused a shutdown; power supply failed
(overvoltage/undervoltage, overtemperature, overcurrent,
short-circuit), fan failed, or input overvoltage protection
No power present or standby power failed (overvoltage/
undervoltage, overtemperature, overcurrent, short-circuit,
fan lock)
Component identification
21