T-10 Torx screwdriver
The components included with the hardware option kit
Storage controller backup power cable (ships with the storage controller)
Make sure that a supported Smart Array P-class Gen10 controller is installed.
Procedure
1.
Observe the following alerts:
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system
components to cool before touching them.
CAUTION: To prevent damage to electrical components, properly ground the server before beginning any
installation procedure. Improper grounding can cause electrostatic discharge.
2.
Back up all server data.
3.
Power down the server.
4.
Disconnect all peripheral cables from the server.
5.
Remove the system board module from the chassis.
6.
Place the system board module on a flat, level work surface.
7.
Remove the system board module access panel.
8.
Install the HPE Smart Storage Battery into the socket.
9.
Install the HPE Smart Storage Battery into the system board module and connect the storage controller backup
power cable.
Hardware options installation