3.8 Modbus Engineering Data Format
Table
Type Code
60
61
62
63
64
65
66
67
68
69
6A
6B
6C
70
71
72
73
74
75
76
77
The under range value is –32768 and the over range value
is +32767. For the hex data format, please refer to Section
1.10.
130
tM-TH8 User Manual, Rev: A1.1 7MH-018-A11
Thermistor Type
PreCon Type III 10K @
25°C
Fenwell Type U 2K @
25°C
Fenwell Type U 2K @
25°C
YSI L Mix 100 @ 25°C
YSI L Mix 300 @ 25°C
YSI L Mix 1000 @ 25°C
YSI B Mix 2252 @ 25°C
YSI B Mix 3000 @ 25°C
YSI B Mix 5000 @ 25°C
YSI B Mix 6000 @ 25°C
YSI B Mix 10000 @ 25°C
YSI H Mix 10000 @ 25°C
YSI H Mix 30000 @ 25°C
User-defined
User-defined
User-defined
User-defined
User-defined
User-defined
User-defined
User-defined
-F.S.
+F.S.
-3000
24000
-5000
15000
0
15000
-8000
10000
-8000
10000
-7000
10000
-5000
15000
-4000
15000
-4000
15000
-3000
15000
-3000
15000
-3000
15000
-1000
20000
-5000
15000
-5000
15000
-5000
15000
-5000
15000
-5000
15000
-5000
15000
-5000
15000
-5000
15000