tM-TH8
Examples:
Command: @01GAT70
Reads the A coefficient of type 70 of module 01 and
returns a value of 3A94030A, which is equivalent to
1.129241x10
Command: @01GBT70
Reads the B coefficient of type 70 of module 01 and
returns a value of 39757ACF, which is equivalent to
2.341077x10
Command: @01GCT70
Reads the C coefficient of type 70 of module 01 and
returns a value of 33BC73A5, which is equivalent to
8.775468x10
Related Commands:
Section 2.32 @AARTTttR(data), Section 2.33
@AASxTttC(data)
Related Topics:
Section 1.11 User-defined Types, Section A.5 Thermistor
94
tM-TH8 User Manual, Rev: A1.1 7MH-018-A11
Response: !013A94030A
-3
.
Response: !0139757ACF
-4
.
Response: !0133BC73A5
-8
.