12 Troubleshooting
Digital Operator Display
to
Cause
Option hardware fault
Digital Operator Display
Cause
Non-compatible option connected to drive port
CN5-B
Digital Operator Display
Cause
Options AI-A3 or D1-A3 connected to the CN5-B
port while an option was connected to CN5-A
Digital Operator Display
Cause
Non-compatible option connected to port CN5-C
Digital Operator Display
Cause
Options AI-A3 or D1-A3 connected to the CN5-C
port while an option was connected to CN5-A
Minor Faults and Alarms
Digital Operator Display
Cause
Communication wiring or terminal resistor
connection is faulty. There is a short circuit, or an
option component is not connected properly
Master-side programming error
Damaged communication circuitry
Explicit Message Communications Errors
When there is a problem with a request message sent from the master in explicit communications, the drive will return a
response message with a service code of "94" and an error code from
Table 20 Explicit Message Error Codes, Causes, and Possible Solutions
Error Code
Description
08FF
Service not supported
09FF
Invalid attribute value
0CFF
Object state conflict
0EFF
Attribute not settable
13FF
Not enough data
14FF
Attribute not supported
74
Option Fault (CN5-A)
oFA30 to oFA43
Communication ID error.
Replace the option. Contact Yaskawa for assistance.
Non-Compatible Option connected to drive port CN5-B
oFb00
Non-compatible option is connected.
Use only compatible options. Connect the SI-N3 to CN5-A. For other option connections refer
to the Installation Manual for those options.
Option Fault (CN5-B)
oFb02
Two of the same option are connected simultaneously.
Only one of these options, AI-A3, DI-A3 or SI-
same time. The SI-N3 must be connected to CN5-A.
Non-Compatible Option connected to drive port CN5-C
oFc00
Non-compatible option is connected.
Use only compatible options. Connect the SI-N3 to CN5-A. For other option connections refer
to the Installation Manual for those options.
Option Fault (CN5-C)
oFc02
Two of the same options are connected simultaneously.
Only one of these options, AI-A3, DI-A3 or SI-
same time. The SI-N3 must be connected to CN5-A.
Serial Communication Transmission Error
CALL
Communication has not yet been established.
Check for wiring errors and correct the wiring.
Remove any ground shorts and reconnect loose wires.
Check communications at start-up and correct programming errors.
Perform a self-diagnostics check and replace the drive if the fault continues
to occur.
The service code is incorrect.
The attribute is incorrect.
Attempted to change a drive constant that
cannot be changed while the drive is running.
Attempted to change a read-only attribute.
The data size is incorrect.
Attempted to execute a service that is not
defined for the attribute.
Possible Solution
Possible Solution
Possible Solution
Possible Solution
Possible Solution
Minor Fault Name
Possible Solution
Table 20
Cause
Correct the service code.
Correct the attribute.
Stop the drive.
Correct the service code or attribute setting.
Correct the data size.
Correct the service code or attribute setting.
YASKAWA ELECTRIC SIEP C730600 43B 1000-Series Option SI-N3 Technical Manual
Fault Name
Fault Name
Fault Name
option can be connected to the drive at the
Fault Name
Fault Name
option can be connected to the drive at the
as the data.
Possible Solution
Minor Fault
(H2-
= 10)
Yes

Advertisement

Table of Contents
loading

This manual is also suitable for:

Si-n3

Table of Contents