8 Output Assemblies (Drive Consumes)
Parameter
NetCtrl
Torque Command 2 (Vendor Specific Yaskawa Electric (YE) Assy) - 123 (0x7B)
Output Instance
Byte
0
1
123
2
3
4
5
Parameter
Run Fwd
Run Rev
Multi-Function Input 3
Multi-Function Input 4
Multi-Function Input 5
Multi-Function Input 6
Multi-Function Input 7
Multi-Function Input 8
External Fault
Fault Reset
Torque Reference/Torque Limit
NetRef
NetCtrl
36
Run command form Network
0x00: Depends on b1-02
0x01: Enables the run command from network
Bit 7
Bit 6
Multi-
Multi-
Function
Function
Function
Input 8
Input 7
Input 6
Forward Run Command
0: Stop
1: Forward Run
Reverse Run Command
0: Stop
1: Reverse Run
Terminal S3 Function Input
0: Terminal S3 Function (H1-03) OFF
1: Terminal S3 Function (H1-03) ON
Terminal S4 Function Input
0: Terminal S4 Function (H1-04) OFF
1: Terminal S4 Function (H1-04) ON
Terminal S5 Function Input
0: Terminal S5 Function (H1-05) OFF
1: Terminal S5 Function (H1-05) ON
Terminal S6 Function Input
0: Terminal S6 Function (H1-06) OFF
1: Terminal S6 Function (H1-06) ON
Terminal S7 Function Input
0: Terminal S7 Function (H1-07) OFF
1: Terminal S7 Function (H1-07) ON
Terminal S8 Function Input
0: Terminal S8 Function (H1-08) OFF
1: Terminal S8 Function (H1-08) ON
External Fault EF0
0: No External Fault (EF0)
1: External Fault (EF0)
Fault Reset
0: No Fault Reset
1: Fault Reset
Torque Reference/Torque Limit
Sets the torque reference and torque limit in units of 0.1%.
Sets the torque reference when using torque control (d5-01 = 1).
Sets the torque limit when using speed control (d5-01 = 0).
The torque reference and torque limit are disabled when F6-06 = 0.
Speed reference from Network
0x00: Depends on b1-01
0x01: Enables the speed reference from network
Run command from Network
0x00: Depends on b1-02
0x01: Enables the run command from network
Data
Bit 5
Bit 4
Bit 3
Multi-
Multi-
Multi-
Function
Function
Input 5
Input 4
Torque Reference/Torque Limit (Low Byte)
Torque Reference/Torque Limit (High Byte)
NetRef
NetCtrl
Data
YASKAWA ELECTRIC SIEP C730600 43B 1000-Series Option SI-N3 Technical Manual
Bit 2
Bit 1
Multi-
Run
Function
Rev
Input 3
Fault
Reset
Bit 0
Run
Fwd
External
Fault