Parameter
Actual Current
Current & Speed Status (Vendor Specific Yaskawa Electric (YE) Assy) - 132 (0x84)
Input
Byte
Instance
0
1
132
2
3
4
5
Parameter
Running
ZSP
REV Running
Reset
Speed Agree
READY
ALARM
FAULT
Uv
LOCAL/REMOTE
Multi-Function Digital Output
Multi-Function Photocoupler 1
Multi-Function Photocoupler 2
YASKAWA ELECTRIC SIEP C730600 43B 1000-Series Option SI-N3 Technical Manual
Actual Output Current
Monitors drive output current
Unit is 0.1 A
Unit is not affected by Current Scale CS.
Bit 7
Bit 6
FAULT
ALARM
ZSV
Photocoupler 2
Running
0: Stop
1: Forward or Reverse Running
Zero Speed
0: Running
1: Stop or DC Injection Braking
Reverse Running
0: Not Reverse Running
1: Reverse Running
Reset
0: No Reset
1: Reset
Speed Agree
0: No Speed Agree
1: Actual speed at speed reference
Drive Ready
0: Not Ready
1: Ready
Drive Alarm
0: No Drive Alarm
1: Alarm
Drive Fault
0: No Drive Fault
1: Fault
Undervoltage
0: No Undervoltage
1: Undervoltage
Status of Run command from Network
0: Run command is not from network
1: Run command is from network
Terminal M1/M2
0: Terminal M1/M2 OFF
1: Terminal M1/M2 ON
Terminal P1
0: Terminal P1 OFF
1: Terminal P1 ON
Terminal P2
0: Terminal P2 OFF
1: Terminal P2 ON
Data
Bit 5
Bit 4
Speed
READY
Agree
Multi-
Multi-
Function
Function
Photocoupler 1
Digital Output
Actual Current (Low Byte)
Actual Current (High Byte)
Output Frequency (Low Byte)
Output Frequency (High Byte)
Data
9 Input Assemblies (Drive Produces)
Bit 3
Bit 2
REV
Reset
Running
Multi-
LOCAL/
Function
REMOTE
Bit 1
Bit 0
ZSP
Running
Uv
45