Download Print this page
YASKAWA 1000 Series Installation Manual

YASKAWA 1000 Series Installation Manual

Analog monitor
Hide thumbs Also See for 1000 Series:

Advertisement

Quick Links

YASKAWA 1000-Series Option
Analog Monitor
Installation Manual
Type AO-A3
To properly use the product, read this manual thoroughly and retain
for easy reference, inspection, and maintenance. Ensure the end user
receives this manual.
1000
安川 
シリーズ オプション
アナログモニタ
取扱説明書
形式
AO-A3
製品を安全にご使用いただくために,この取扱説明書を必ずお読みください。
また,本書をお手元に保管していただくとともに,最終的に本製品をご使用になる
ユーザー様のお手元に確実に届けられるよう,お取り計らい願います。
MANUAL NO. TOBP C730600 40E

Advertisement

loading
Need help?

Need help?

Do you have a question about the 1000 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for YASKAWA 1000 Series

  • Page 1 YASKAWA 1000-Series Option Analog Monitor Installation Manual Type AO-A3 To properly use the product, read this manual thoroughly and retain for easy reference, inspection, and maintenance. Ensure the end user receives this manual. 1000 安川  シリーズ オプション アナログモニタ 取扱説明書 形式 AO-A3 製品を安全にご使用いただくために,この取扱説明書を必ずお読みください。...
  • Page 2 Yaskawa. No patent liability is assumed with respect to the use of the information contained herein. Moreover, because Yaskawa is constantly striving to improve its high-quality products, the information contained in this manual is subject to change without notice.
  • Page 3: Table Of Contents

    8 SPECIFICATIONS ....... 25 YASKAWA ELECTRIC TOBP C730600 40E 1000-Series Option AO-A3 Installation Manual...
  • Page 4: Preface And Safety

    Under no circumstances should any Yaskawa product be incorporated into any product or design as the exclusive or sole safety control. Without exception, all controls should be designed to detect faults dynamically and fail safely under all circumstances.
  • Page 5 Indicates a hazardous situation, which, if not avoided, could result in death or serious injury. CAUTION Indicates a hazardous situation, which, if not avoided, could result in minor or moderate injury. YASKAWA ELECTRIC TOBP C730600 40E 1000-Series Option AO-A3 Installation Manual...
  • Page 6 • When ordering new copies of the manual, contact a Yaskawa representative or the nearest Yaskawa sales office and provide the manual number shown on the front cover.
  • Page 7: Product Overview

    The option can be used with the unit models in Table Table 1 Applicable Models Unit Series Unit Model Number A1000 All models L1000A All models D1000 All models R1000 All models YASKAWA ELECTRIC TOBP C730600 40E 1000-Series Option AO-A3 Installation Manual...
  • Page 8: Receiving

    • A small file or medium grit sandpaper. (required for some unit models) Note: Tools required to prepare option cables for wiring are not listed in this manual. <1> Select a screwdriver appropriate for the unit capacity. YASKAWA ELECTRIC TOBP C730600 40E 1000-Series Option AO-A3 Installation Manual...
  • Page 9: Option Components

    Figure 1 Analog Monitor AO-A3 Option Components ◆ Terminal Block TB1 V1 AC V2 AC Refer to Table 4 on page for details on TB1 terminal functions and signal levels. YASKAWA ELECTRIC TOBP C730600 40E 1000-Series Option AO-A3 Installation Manual...
  • Page 10: Installation Procedure

    Do not touch circuit boards while the power to the unit is on. Failure to comply could result in death or serious injury. YASKAWA ELECTRIC TOBP C730600 40E 1000-Series Option AO-A3 Installation Manual...
  • Page 11 Do not use unshielded cable for control wiring. Failure to comply may cause electrical interference resulting in poor system performance. Use shielded twisted-pair wires and ground the shield to the ground terminal of the unit. YASKAWA ELECTRIC TOBP C730600 40E 1000-Series Option AO-A3 Installation Manual...
  • Page 12 Failure to comply may prevent proper operation and possibly damage equipment. Check wiring to ensure that all connections are correct after installing the option and connecting any other devices. Failure to comply may result in damage to the option. YASKAWA ELECTRIC TOBP C730600 40E 1000-Series Option AO-A3 Installation Manual...
  • Page 13 D – Digital operator J – Connector CN5-A E – Terminal cover K – Connector CN5-B F – Removable tabs for wire routing L – Connector CN5-C Figure 2 Unit Components with Option YASKAWA ELECTRIC TOBP C730600 40E 1000-Series Option AO-A3 Installation Manual...
  • Page 14 NOTICE: Damage to Equipment. Observe proper electrostatic discharge procedures (ESD) when handling the option, unit, and circuit boards. Failure to comply may result in ESD damage to circuitry. Figure 3 Figure 3 Remove the Front Cover, Terminal Cover, and Digital Operator YASKAWA ELECTRIC TOBP C730600 40E 1000-Series Option AO-A3 Installation Manual...
  • Page 15 Insert the option card (B) into the CN5-A (J), CN5-B (K), or CN5-C (L) connector located on the unit and fasten it into place using one of the included screws (G). Figure 4 Figure 4 Insert the Option Card YASKAWA ELECTRIC TOBP C730600 40E 1000-Series Option AO-A3 Installation Manual...
  • Page 16 2. There are two screw holes on the unit for use as ground terminals (J). When connecting three options, two ground wires will need to share the same unit ground terminal. YASKAWA ELECTRIC TOBP C730600 40E 1000-Series Option AO-A3 Installation Manual...
  • Page 17 Loosen the screws and Option terminal block insert the wire into the opening on the terminal block. To customer circuit (do not solder ends) Figure 7 Preparing and Connecting Cable Wiring YASKAWA ELECTRIC TOBP C730600 40E 1000-Series Option AO-A3 Installation Manual...
  • Page 18 (24 to 17 AWG) 0.25 to 0.5 twisted AC, FE (1.95 to 2.21) (18 AWG) Solid wire: (20 AWG) (24 to 20 AWG) pair, etc. 0.25 to 1.5 (24 to 16 AWG) YASKAWA ELECTRIC TOBP C730600 40E 1000-Series Option AO-A3 Installation Manual...
  • Page 19 5 Installation Procedure Ferrule-Type Terminals Yaskawa recommends using CRIMPFOX 6 by Phoenix Contact or equivalent ferrule-type terminals with the specifications listed in Table 5 for wiring to ensure proper connections. Note: Properly trim wire ends so loose wire ends do not extend from the crimp terminals.
  • Page 20 9-B for units that do not require routing through the front cover. Refer to the Peripheral Devices & Options section of the unit Instruction Manual for more information. Figure 9 Figure 9 Wire Routing Examples YASKAWA ELECTRIC TOBP C730600 40E 1000-Series Option AO-A3 Installation Manual...
  • Page 21 Note: Take proper precautions when wiring the option so that the front covers will easily fit back onto the unit. Make sure cables are not pinched between the front covers and the unit when replacing the covers. Set unit parameters in Table 5 for proper option performance. YASKAWA ELECTRIC TOBP C730600 40E 1000-Series Option AO-A3 Installation Manual...
  • Page 22: Related Parameters

    Terminal V2 Signal Level (398) Range: 0, 1 <1> The unit outputs voltage while this parameter is being adjusted. Voltage levels can be adjusted to match the specifications of an external meter. YASKAWA ELECTRIC TOBP C730600 40E 1000-Series Option AO-A3 Installation Manual...
  • Page 23: Troubleshooting

    Option connection error at unit port CN5-C Cause Possible Solution Option at unit port CN5-C was changed during Turn the power off and check the connectors between the unit run. and option. YASKAWA ELECTRIC TOBP C730600 40E 1000-Series Option AO-A3 Installation Manual...
  • Page 24 • Limit the length of wiring under 50 m (164 ft.). • Separate the control wiring to the option, main circuit wiring, and power lines. Interface Circuit ■ Figure 11 – V1, V2 Signal processor Figure 11 Output Interface Circuit YASKAWA ELECTRIC TOBP C730600 40E 1000-Series Option AO-A3 Installation Manual...
  • Page 25: Specifications

    -20°C to +60°C (-4°F to +140°F) allowed for short-term transport of the product Area of use Indoor (free of corrosive gas, airborne particles, etc.) Altitude 1000 m (3280 ft.) or lower YASKAWA ELECTRIC TOBP C730600 40E 1000-Series Option AO-A3 Installation Manual...
  • Page 26 Revision: Address Entire document Edited for procedural clarity and readability. July 2010 <2> Back cover Revision: Address May 2010 <1> Back cover Revision: Address − − July 2008 First edition YASKAWA ELECTRIC TOBP C730600 40E 1000-Series Option AO-A3 Installation Manual...
  • Page 27 Phone: +81-3-5402-4502 Fax: +81-3-5402-4580 http://www.yaskawa.co.jp YASKAWA AMERICA, INC. 2121, Norman Drive South, Waukegan, IL 60085, U.S.A. Phone: +1-800-YASKAWA (927-5292) or +1-847-887-7000 Fax: +1-847-887-7310 http://www.yaskawa.com YASKAWA ELÉTRICO DO BRASIL LTDA. 777, Avenida Piraporinha, Diadema, São Paulo, 09950-000, Brasil Phone: +55-11-3585-1100 Fax: +55-11-3585-1187 http://www.yaskawa.com.br...