YASKAWA 1000 Series Technical Manual page 57

Ac drive
Hide thumbs Also See for 1000 Series:
Table of Contents

Advertisement

Parameter
Multi-Function Input 3
Multi-Function Input 4
Multi-Function Input 5
Multi-Function Input 6
Multi-Function Input 7
Multi-Function Input 8
Multi-Function Digital Output
Multi-Function Photocoupler 1
Multi-Function Photocoupler 2
Analog Input 1
Output Frequency
Enhanced Torque Status, Dynamic (Vendor Specific Yaskawa Electric (YE) Assy) -
158 (0x9E)
Input Instance
Byte
0
1
Photocoupler 2
158
2
3
4
5
6
7
Parameter
Running
ZSP
REV Running
YASKAWA ELECTRIC SIEP C730600 43B 1000-Series Option SI-N3 Technical Manual
Terminal S3
0: Terminal S3 OFF
1: Terminal S3 ON
Terminal S4
0: Terminal S4 OFF
1: Terminal S4 ON
Terminal S5
0: Terminal S5 OFF
1: Terminal S5 ON
Terminal S6
0: Terminal S6 OFF
1: Terminal S6 ON
Terminal S7
0: Terminal S7 OFF
1: Terminal S7 ON
Terminal S8
0: Terminal S8 OFF
1: Terminal S8 ON
Terminal M1/M2
0: Terminal M1/M2 OFF
1: Terminal M1/M2 ON
Terminal P1
0: Terminal P1 OFF
1: Terminal P1 ON
Terminal P2
0: Terminal P2 OFF
1: Terminal P2 ON
Analog Input A1
Actual Drive Speed
Monitors drive output frequency
Unit depends on o1-03.
Unit is not affected by Speed Scale SS.
Bit 7
Bit 6
FAULT
ALARM
Multi-
Multi-
Function
Function
Photocoupler 1
Running
0: Stop
1: Forward or Reverse Running
Zero Speed
0: Running
1: Stop or DC Injection Braking
Reverse Running
0: Not Reverse Running
1: Reverse Running
Data
Bit 5
Bit 4
Speed
READY
Agree
Multi-
Function
LOCAL/
Code High
Digital
REMOTE
Output
Actual Torque (Low Byte)
Actual Torque (High Byte)
Register Number (Low Byte)
Register Number (High Byte)
Register Data (Low Byte)
Register Data (High Byte)
Data
9 Input Assemblies (Drive Produces)
Bit 3
Bit 2
REV
Reset
Running
Function
Function
Code Low Bit
Bit
Bit 1
Bit 0
ZSP
Running
Uv
oPE
57

Advertisement

Table of Contents
loading

This manual is also suitable for:

Si-n3

Table of Contents