Page 1
YASKAWA AC Drive Option LED Operator Installation Manual Type JVOP-182 To properly use the product, read this manual thoroughly and retain for easy reference, inspection, and maintenance. Ensure the end user receives this manual. 安川インバータ オプション オペレータ 取扱説明書 形式 JVOP-182 製品を安全にお使い頂くために,この取扱説明書を必ずお読みください。...
Yaskawa. No patent liability is assumed with respect to the use of the information contained herein. Moreover, because Yaskawa is constantly striving to improve its high-quality products, the information contained in this manual is subject to change without notice.
The selection and application of Yaskawa products remain the responsibility of the equipment manufacturer or end user. Yaskawa accepts no responsibility for the way its products are incorporated into the final system design. Under no circumstances should any Yaskawa product be incorporated into any product or design as the exclusive or sole safety control.
Page 4
To conform to requirements, make sure Other areas: contact a Yaskawa representative. to ground the supply neutral for 400V class. 危 険 けが、感電のおそれがあります。 据え付け、運転の前には必ず取扱説明書を読むこと。 通電中および電源遮断後 分以内はフロントカバーを 外さないこと。 400V 級インバータの場合は、電源の中性点が接地 されていることを確認すること。( 対応) YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual...
Page 5
Indicates a hazardous situation, which, if not avoided, could result in death or serious injury. CAUTION Indicates a hazardous situation, which, if not avoided, could result in minor or moderate injury. YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual...
Page 6
• When ordering a new copy of the manual due to damage or loss, contact your Yaskawa representative or the nearest Yaskawa sales office and provide the manual number shown on the front cover.
The LED Operator Option provides an enhanced drive user interface that can operate the Yaskawa drive at a short distance up to 3 meters. The LED Operator Option is an LED display that simplifies the task of interfacing with the drive to perform these tasks: •...
Refer to Installing the LED Operator Option on page 17 more information regarding installation methods. To order a cable or an installation support, contact Yaskawa directly or your nearest Yaskawa distributor. YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual...
Page 9
External/Face Mount – Phillips screwdriver, M3 Installation Set A Phillips screwdriver, M3, M4 Internal/Flush Mount Phillips screwdriver, M3 Installation Set B Box end or adjustable wrench, M4 YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual...
A – Data Display Area D – Installation Mounting Holes B – LED Indicators E – Nameplate C – Keys F – Communication Cable Connector Figure 1 LED Operator Option Components YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual...
Page 11
RUN Key Starts the drive and motor. R R U U N Up Arrow Scrolls up to display the next item, selects parameter numbers and increments setting values. YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual...
Page 12
Refer to LED Screen Display on page 15 DRV LED Light FOUT LED Light <1> o2-01(LOCAL/REMOTE Key Function Selection) is not compatible with J1000. LO/RE Selection Key is always effective. YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual...
Page 13
<1> For the difference between “Flashing” and “Flashing Quickly” of the RUN LED, refer to Figure 3, RUN LED Status. Figure 3 Flashing Flashing quickly Figure 3 RUN LED Status YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual...
Page 14
Drive Mode – Programming Mode Displays output frequency (Hz) – – DIGITAL OPERATOR JVOP-182 DIGITAL OPERATOR JVOP-182 DIGITAL OPERATOR JVOP-182 As illustrated FOUT FOUT FOUT in this manual YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual...
Failure to comply may prevent proper operation and possibly damage equipment. Do not exceed communication cable bend radius specifications. Failure to comply may result in broken wires or loose connections. YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual...
Page 16
Table 7 LED Operator Option Installation Methods Installation Method Description Notes Simplified installation with the LED Operator is External/Face-mount mounted on the outside of the panel with two – screws. YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual...
Page 17
× 2 Enclosure panel Unit: mm (in) Figure 6 External/Face-mount Installation Figure 7 22 (0.87) 22(0.87) (0.55) Unit : mm (in) Figure 7 Panel Cut-out Dimensions (External/Face-mount Installation) YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual...
Page 18
LED Operator Option. Figure 9 45 (1.77) +0.5 2.32 +0.02 Unit : mm (in) Figure 9 Panel Cut-out Dimensions (Internal/Flush-mount Installation) YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual...
Page 19
10 for information regarding recommended cables. Note: Use only Yaskawa recommended cables. Using a cable not specified may cause the LED Operator or drive to malfunction. Note: The STOP key on the drives built-in LED operator is the only functional key on the built-in LED operator when the LED Operator Option is connected to the drive and parameter b1-02 is set to 0 (LED Operator Option).
Page 20
Numbers (Sold Separately) on page 10 for information regarding recommended cables. NOTICE: Use only Yaskawa recommended cables. Using a cable not specified may cause the LED Operator or drive to malfunction. Note: The STOP key on the drives built-in LED operator is the only functional key on the built-in LED operator when the LED Operator Option is connected to the drive and parameter b1-02 is set to 0 (LED Operator Option).
The LED Operator Option can perform the Read function an estimated 100,000 times. Copy Copies the parameter settings from the LED Operator Option to another Yaskawa drive. Verify Verifies parameter settings in the drive match parameter settings saved to the LED Operator Option.
Page 22
6. Automatically return to the Copy Function Selection display. DIGITAL OPERATOR JVOP-182 7. Press repeatedly until the display returns to the initial FOUT display. YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual...
1: Enabled Enables/Disables the operator panel STOP key when STOP Key the drive is operated form external sources (not o2-02 Function operator). Selection 0: Disabled 1: Enabled YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual...
Page 24
Copy Allowable 0: Disabled - Read not allowed 1: Enabled - Read allowed <1> b1-01 = 4 and b1-02 = 3 are not compatible with the J1000 drive. YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual...
LED Operator Option Fault Diagnostics ◆ Error Code and Connection Messages Fault/Error code text will appear on the LED Operator (JVOP-182) display to indicate a specific fault. The fault codes in Table 9 are displayed on the LED operator built in the drive and/or the LED Operator (JVOP-182) displays.
Page 26
• Turn off the drive input power and disconnect the LED Operator (JVOP-182). Reconnect the LED Operator (JVOP-182) and reapply drive input power. <1> Display will vary depending on operation status. YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual...
Indoor (free of corrosive gas, airborne particles, etc.) Altitude Up to 1000 m 10 to 20 Hz : 9.8 m/s Shock 20 to 55 Hz : 5.9 m/s Read Function Estimated 100,000 times Limitation YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual...
Revised Content Publication − − March 2008 First edition September 2008 Back cover Revision: Address December 2008 All chapters Revision: Application to the A1000 drive and V1000 drive YASKAWA ELECTRIC TOBP C730600 35B YASKAWA AC Drive Option LED Operator Installation Manual...
Page 29
No.18 Xizang Zhong Road. Room 1702-1707, Harbour Ring Plaza Shanghai 200001, China Phone 86-21-5385-2200 Fax 86-21-5385-3299 YASKAWA ELECTRIC (SHANGHAI) CO., LTD. BEIJING OFFICE Room 1011A, Tower W3 Oriental Plaza, No.1 East Chang An Ave., Dong Cheng District, Beijing 100738, China...
Need help?
Do you have a question about the JVOP-182 and is the answer not in the manual?
Questions and answers