V&T E5 Series User Manual page 45

High performance universal inverter
Table of Contents

Advertisement

Table 4−1 Multi−function
Value
setting
Function
(P2.01)
0
No function
T
JOG
Emergency stop T
T
(stop in shortest time)
Emergency stop T
3
(coast to stop)
Switchover of run
4
command channel
Switchover of
5
parameters displayed
mode FAStTbASE
Switchover of
6
parameters displayed
mode ndFtTbASE
Switchover of
7
parameters displayed
mode LAStTbASE
Switchover of
8
parameters displayed
mode
32
E5 Series High Performance Universal Inverter
key function selection and the meanings of MULTI indicator
M
M key is defined as no function.
Used as JOG operation key and is only
enabled when run command is given via
operation panel
In stop status, press M key to enter jog
operation status, and release this key to stop
Press M key, inverter will stop in shortest time
Press M key, inverter will coast to stop
Press M key to switch the run command
channel:
Operation panel→Terminal → Communication
→ Operation panel.
During switchover time, there is a 5−second
response time limit and the change is
canceled automatically after 5−second time is
exceeded. Within 5s, press PRG key to
confirm the change. MON indicator indicates
the run command channel
Press M key to switch between FASt and
bASE parameters displayed mode panel
should prompt as FASt and bASE
Press M key to switch between ndFt and bASE
parameters displayed mode, the indications on
the operation panel are ndFt and bASE
respectively
Press M key to switch between LASt and
bASE parameters displayed mode, the
indications on the operation panel are LASt
and bASE respectively
bASE→FASt→ndFt→LASt→bASE
Chapter 4 Operation Panel
User's Manual
Descriptions
Meanings of MULTI
indicator
Normally Off: No function
On: Press M
Off: Release M to finish the
jog operation
On: Press M
Off: Release M
On: Press M
Off: Release M
On: Press M
Off: M key has been released
for more than 5s or PRG
key has been used to
confirm the changing of
the run command source
On: FASt, fast parameters
displayed mode
Off: bASE, basic parameters
displayed mode
On: ndFt,non−factory setting
parameters displayed
mode
Off: bASE, basic parameters
displayed mode
On: LASt, last change T0
parameters
displayed
mode
Off: bASE, basic parameters
displayed mode
On: non−bASE basic
parameters displayed
mode
Off: bASE, basic parameters
displayed mode