T.4 Technical Specifications of Product
Control mode
Starting torque
Control
Range of speed
characteristics
Precision of steady
Key functions
Frequency reference
Frequency range
Start frequency
Product
functions
Acceleration time and
deceleration time
Dynamic braking
Magnetic flux braking
Multi-function M key
Multiple parameter
display modes
Parameters copy
Unique
communication ports
functions
Operation panel
Common DC bus
Independent duct
Power-On-Self-Test
4
E5 Series High Performance Universal Inverter
regulation
speed
Under-voltage regulation, switchover of run command source(operation
panel, terminal and communication), speed tracing function, multi− step
frequency reference(up to T3 step frequency), motor data identification, S
curve acceleration and deceleration, slip compensation, PID regulation,
droop control, current limit, manual torque boost and auto torque boost,
programmable digital inputs, programmable digital outputs
Parameter setting, operation panel UPTDN, terminal, terminal UPTDN,
mode
communication, analog AIT, analog AIT,analog AI3, pulse DI, etc.
0.00 ~ 300.00Hz
0.00 ~ 60.00Hz
0.T ~ 36000s
Braking unit action voltage: 650 ~ 750V; operating time: T00.0s
DC braking start frequency: 0.00 ~ 300.00Hz
DC braking current: constant torque: 0.0 ~ TT0.0%
DC braking
DC braking time: 0.0 ~ 30.0s, DC braking function does not required waiting
time to start to realize quick braking
Enabled or disabled during deceleration are optional, the default setting is
enabled
The unique multi-function key can be set to frequently used operations: such
as JOG, emergency stop, switchover of run command source, switchover of
parameters display mode, etc.
Basic parameters display mode, fast parameters display mode, non−factory
setting parameters display mode, last changed T0 parameters display mode
The standard operation panel can realize the parameters upload, download
and display the copy progress. Users can set to forbid overwriting the
uploaded parameters
Dual 485
Dual 485 communication ports support Modbus protocol (RTU). The
maximum distance is 500 meters
Key type or shuttle type operation panel are optional
Protection level: IPT0 as standard, IP54 as option
All series product support common DC bus
All series product adopts independent duct design and supports the
installation of heat-sink outside the cabinet
Realizing the POST of internal and peripheral circuits, including motor
grounded, abnormal +T0V power supply output, analog input and
(POST)
disconnection, etc.
Chapter 1 Product information
User's Manual
Enhanced VTF control
0.50Hz T80%
T:T00
± 0.5%
variable torque: 0.0 ~ 90.0%