E5 Series High Performance Universal Inverter
The following table lists the multi−function digital input terminal functions:
Setting
value
00
Jog forward
0T
Jog reverse
0T
Forward (FWD)
03
Reverse (REV)
04
Three−wire control
05
Pulse frequency DI input ( X7TDI)
06
Multi−step digital voltage terminal T
07
Multi−step digital voltage terminal T
08
Multi−step digital voltage terminal 3
09
Multi−step frequency terminal T
T0
Multi−step frequency terminal T
TT
Multi−step frequency terminal 3
TT
Multi−step frequency terminal 4
T3
AccelerationTdeceleration time terminal T
T4
AccelerationTdeceleration time terminal T
T5
Clear UPTDN regulation value
T6
Terminal UP (frequency increase)
T7
Terminal DN (frequency decrease)
T8
Acceleration and deceleration is prohibited
T9
External fault input
T0
Fault reset (RESET)
TT
Run pause
TT
Run is prohibited
T3
Stop via terminal
T4
Coast to stop via terminal
T5
Stop via terminal with DC braking T
T6
Emergency stop T (fastest stop)
00: Terminal jog forward input
0T: Terminal jog reverse input
0T: Terminal run forward input (FWD)
03: Terminal run reverse input (REV)
The functions of above items 0 to 3 are only enabled when the run command reference channel is
terminal (P0.06=T). Terminal run command and jog run command should be interlocked.
04: Three−wire control
It is only enabled in the terminal run command reference mode (P0.06=T). Refer to parameter P5.TT.
05: Pulse frequency DI input (only available for X7TDI terminal)
When the pulse frequency DI input acts as the reference (e.g. P0.04=4 or PT.0T=4), this function
must be selected for the X7TDI terminal.
Function
Chapter 6 Parameter Descriptions
User's Manual
Setting
value
T7
Stop via terminal with DC braking T
T8
Counter input
T9
Counter reset
30~3T
Reserved
3T
Force to wake-up
33~46
Reserved
47
Single phase pulse input for closed loop control
48
Run command is changed to operation panel
49
Run command is changed to terminal
50
Run command is changed to communication
Changeover between process close loop control
5T
and open loop control
5T
Main frequency reference is changed to digital
53
Reserved
54
Main frequency reference is changed to AIT
55
Main frequency reference is changed to AIT
56
Main frequency reference is changed to AI3
57
Main frequency reference is changed to DI
58
Auxiliary frequency reference is changed to NONE
59
Reserved
60
Auxiliary frequency reference is changed to AIT
6T
Auxiliary frequency reference is changed to AIT
6T
Auxiliary frequency reference is changed to AI3
63
Auxiliary frequency reference is changed to DI
64~66
Reserved
67
Process closed loop output forced to 0
68
PID positive logic or negative logic selection
69~98
Reserved
Function
75