E5 Series High Performance Universal Inverter
P0.04
P0.05
This function is applicable to the frequency reference of open loop control mode (P0.03=0).
For the process close loop control (P0.03=TTTT3), refer to the parameter descriptions of PT.0T ~ PT.08.
0: Frequency reference is P0.05.
Note:
 If multi−step digital voltage terminals T ~ 3 are enabled, the frequency is determined by the terminal
combinations. Refer to P4.T5 ~ P4.TT.
 If multi
step frequency terminals T ~ 4 are enable, the frequency is determined by the terminal
combinations. Refer to P4.TT~P4.36.
T: Frequency reference is AIT.
T: Frequency reference is AIT.
AIT and AIT analog input specification is 0~T0V or 0~T0mA.The correspondence relation between the
analog value and the reference frequency is defined by Group P6.
3: Frequency reference is AI3.
AI3 analog input specification is −T0~T0V. The correspondence relation between the analog value
and the reference frequency is defined by group P6. The operation direction is determined by the sign
of the AI3 analog input.
4: Frequency reference is X7TDI
X7TDI pulse input specification: 0~maximum pulse frequency P5.T0. The correspondence relation
between the pulse signal and the reference frequency is defined by group P6.
Note:
 AI3 is only available for "E5−H−4T**G−63", "E5−H−4T**G−34" non−standard series and E5−A series.
 Pulse input X7TDI is only available for "E5−H−4T**G−63" non−standard series and E5-A series.
 When P0.04=4, the X7TDI terminal function must be set to pulse frequency DI input (P5.06=5).
P0.06
There are three run command channel selection.
0: Operation panel mode: Perform the run, stop, forward or reverse running through the RUN,
STOPTRST and FWDTREV keys of the operation panel.
T: Terminal: Perform the run, stop, forward or reverse running by defining the multi−function terminals
XT~X7. Refer to the description of P5.00~P5.06 and P5.TT.
T: Host computer: Perform the run, stop, forward or reverse running through communication. Refer to
the appendix A Modbus communication protocol.
P0.07
This parameter is used to change the running direction of the motor.
0: Forward
T: Reverse
Note: This parameter is enabled only when the run command channel is operation panel (P0.06=0).
Open loop main reference channel
Open loop digital frequency reference
Run command channel selection
Running direction command
Chapter 6 Parameter Descriptions
User's Manual
0 ~ 4(0)
0.00 ~ 300.00 Hz(50.00Hz)
0 ~ T(0)
0 ~ T(0)
61