V&T E5 Series User Manual page 70

High performance universal inverter
Table of Contents

Advertisement

No.
Name
Process closed loop
function selection for
H0.00
constant pressure
control
The pressure
H0.0T
corresponding to
maximum analog
Upper limit of
H0.0T
pressure setting
Lower limit of
H0.03
pressure setting
Pressure setting
H0.04
channel selection
H0.05 Digital pressure setting
H0.06 Sleep frequency setting
H0.07 Sleep delay time
Wake-up pressure
H0.08
percentage
H0.09 Exit wake-up delay time
H0.T0 Reserved
Frequency of auto
H0.TT
switch acceleration time
and deceleration time
Acceleration time and
deceleration time
H0.TT
automatically switch
selection
Sleep and wake-up
H0.30
mode selection
Wake-up pressure
H0.3T
setting
H0.3T Sleep pressure setting
H0.33 Wake-up delay time
H0.34 Sleep delay time
Group H1
EX-DT0T digital terminal
HT.00
extension card selection
Digital input terminal X8
HT.0T
function selection
Digital input terminal X9
HT.0T
function selection
Digital input terminal
HT.03
XT0 function selection
Digital input terminal
HT.04
XTT function selection
X8~XTT terminal filter
HT.05
time
X8~XTT virtual terminal
HT.06
active selection
E5 Series High Performance Universal Inverter
Default
Range
Group H0
Special Parameters for Constant Pressure Control
0
0 ~ T
T.00
0.00 ~ 655.35 Mpa
T.00
0.00 ~ 655.35 Mpa
0.00
0.00 ~ 655.35 Mpa
0
0 ~ T
0.40
0.00 ~ 655.35 Mpa
30.00
0.0 ~ 300.00
60.0
0.0 ~ 3600.0
50.0
0.0 ~ T00.0
30.0
0.0 ~ 3600.0
0
T
0.00
0.00 ~ 300.00
T
0 ~ 3
0
0 ~ T
0.00
0.0 ~ T0.00
0.00
0.0 ~ T0.00
0.0
0.0 ~ 3600.0
0.0
0.0 ~ 3600.0
Special Parameters for EX-DT01 Digital Terminal Extension Card
T
0 ~ T
99
00 ~ 99
99
00 ~ 99
99
00 ~ 99
99
00 ~ 99
0.00T
0.000 ~ T.000
0
0 ~ T
Chapter 5 Parameter List
User's Manual
Unit Property
0: Disabled
T
×
T: Enabled
×
0.00 ~ 655.35 Mpa
×
0.00 ~ 655.35 Mpa
×
0.00 ~ 655.35 Mpa
0: Digital pressure setting (H0.05)
T
T: AIT
T: AIT
0.00 ~ 655.35Mpa(when H0.04=0)
Hz
0.0 ~ 300.00Hz
s
0.0 ~ 3600.0s
%
0.0 ~ T00.0%
s
0.0 ~ 3600.0s
T
*
Reserved
Hz
0.00 ~ 300.00Hz
0: Acceleration time and deceleration time 0
(P0.08 and P0.09)
T: Acceleration time and deceleration time T
(P4.09 and P4.T0)
s
T: Acceleration time and deceleration time T
(P4.TT and P4.TT)
3: Acceleration time and deceleration time 3
(P4.T3 and P4.T4)
0: According H0.00 setting
T
T: According H0.3T to H0.34 setting
V
0.00 ~ T0.00V
V
0.00 ~ T0.00V
s
0.0 ~ 3600.0s
s
0.0 ~ 3600.0s
0: EX-DT0T is not selected
T
T: EX-DT0T is selected
Refer to the description of P5.00 to P5.06
T
T
T
T
s
0: X8 ~ XTT virtual terminal is inactive
T
T: X8 ~ XTT virtual terminal is active
Description
User
57

Advertisement

Table of Contents
loading

Table of Contents