PT.03
Up to 4 parameters can be set and displayed in stop status, and viewed circularly by pressing >> key.
Ones place
Tens place
Hundreds place
Thousands place
PT.04
PT.05
If the parameter is to be displayed has proportion relation with a physical value in the operation display
parameter defined by PT.0T, PT.04 can be used to designate the physical value as the display
benchmark, and PT.05 can be used to set the coefficient of the display benchmark.
When a parameter is to be displayed (i.e. PT.05≠0), the physical value will be automatically added into
the display parameter in running status and can be viewed by pressing >> key. In this situation, there will
be 5 parameters are displayed. The unit indicator light for the newly added parameter are LED A and
LED V.
PT.06
PT.07
If the parameter is to be displayed has proportion relation with a physical value in the stop display
parameter defined by PT.03, PT.06 can be used to designate the physical value as the display
benchmark, and PT.07 can be used to set the coefficient of the display benchmark.
When a parameter is to be displayed (i.e. PT.07≠0), the physical value will be automatically added into
the display parameter in stop status and can be viewed by pressing >> key. In this situation, there will be 5
parameters are displayed. The unit indicator light for the newly added parameter are LED A and LED V.
68
E5 Series High Performance Universal Inverter
Display parameter selection in stop status
PT.0T Display parameter selection in stop status
0: Reference frequency (Hz)
T: AIT (V)
4: AI3 (V)
6: External counts
8: Close loop reference (%)
A: Reserved
C: Reserved
E: Reserved
Same as above
Same as above
Same as above
Display parameter benchmark in running status
Display parameter coefficient in running status
Display parameter benchmark in stop status
Display parameter coefficient in stop status
Chapter 6 Parameter Descriptions
User's Manual
0000 ~ FFFF (3TT0)
T: Bus voltage (V)
3: AIT (V)
5: DI (%)
7: Motor rotation speed (rpm)
9: Close loop feedback (%)
B: Reserved
D: Reserved
F: Reserved
0 ~ F (0)
0.0 ~ T000.0% (0.0%)
0 ~ F (0)
0.0 ~ T000.0% (0.0%)