T9 Special Parameters For Ex-Dt0T (Group Ht) - V&T E5 Series User Manual

High performance universal inverter
Table of Contents

Advertisement

6.T9 Special Parameters for EX-DT0T (Group HT)

HT.00
If EX-DT0T card is installed, HT.00 should be set to T to enable the function of EX-DT0T.
HT.0T
HT.0T
HT.03
HT.04
HT.05
X8 ~ XTT terminal function and XT ~ X7 terminal function are identical, refer to P5.00 to P5.07 for description.
HT.06
The parameter is used to set the X8 to XTT virtual terminal. Set to "0" is disabled and "T" is enabled .
HT.07
X8 ~ XTT terminal positive logic or negative logic selection
HT.08
HT.09
HT.T0
RAT ~ RA3 terminal function and RA terminal function are identical, refer to P7.0T for description.
HT.TT
The parameter is used to set the RAT to RA3 virtual terminal. Set to "0" is disabled and "T" is enabled .
HT.TT
RAT ~ RA3 terminal positive logic or negative logic selection
HT.T3
HT.T4
HT.T5
E5 Series High Performance Universal Inverter
EX-DT0T digital terminal extension card selection
X8 terminal input function selection
X9 terminal input function selection
XT0 terminal input function selection
XTT terminal input function selection
X8 to XTT terminal filter time
X8 ~ XTT virtual terminal active selection
X8 ~ XTT terminal positive logic or negative logic selection
0: Active if current flowing through, positive logic
T: Active if no current flowing through, negative logic
bit0
X8 positive logic or negative logic selection
bitT
X9 positive logic or negative logic selection
bitT
XT0 positive logic or negative logic selection
bit3
XTT positive logic or negative logic selection
Relay RAT output function selection
Relay RAT output function selection
Relay RA3 output function selection
RAT ~ RA3 virtual terminal active selection
RAT ~ RA3 terminal positive logic or negative logic selection
0: Active if in magnetizing status, positive logic
T: Active if not in magnetizing status, negative logic
bit0
RAT positive logic or negative logic selection
bitT
RAT positive logic or negative logic selection
bitT
RA3 positive logic or negative logic selection
RAT output function action delay time
RAT output function action delay time
RA3 output function action delay time
Chapter 6 Parameter Descriptions
User's Manual
0 ~ T(T)
00 ~ 99(99)
00 ~ 99(99)
00 ~ 99(99)
00 ~ 99(99)
0.000 ~ T.000s (0.00Ts)
0 ~ T (0)
0 ~ F (0)
00 ~ 47 (00)
00 ~ 47 (0T)
00 ~ 47 (0T)
0 ~ T (0)
0 ~ 7 (0)
0.0 ~ 999.9s (0.0s)
0.0 ~ 999.9s (0.0s)
0.0 ~ 999.9s (0.0s)
119

Advertisement

Table of Contents
loading

Table of Contents