TECHTOP TD20 Series Product Manual page 34

Vfd
Table of Contents

Advertisement

TD20 Series VFD
Function
Name
code
Starting
P01.09
frequency of
DC braking
Waiting time
P01.10
before DC
braking
DC braking
P01.11
current
DC braking
P01.12
time
Dead time of
P01.13
FWD/REV
rotation
Detailed instruction of parameters
decreases to 0Hz, the VFD stops.
1: Coast to stop: after the stop command becomes valid,
the VFD ceases the output immediately. And the load
coasts to stop at the mechanical inertia.
Starting frequency of DC braking: start the DC braking
when running frequency reaches starting frequency
determined by P1.09.
Waiting time before DC braking: VFDs blocks the output
before starting the DC braking. After this waiting time,
the DC braking will be started so as to prevent
over-current fault caused by DC braking at high speed.
DC braking current: the value of P01.11 is the
percentage of rated current of VFD. The bigger the DC
braking current is, the greater the braking torque is.
DC braking time: the retention time of DC braking. If the
time is 0, the DC braking is invalid. The VFD will stop at
the set deceleration time.
ACC
P01.04
P13.14
P01.23
Setting range of P01.09: 0.00Hz–P00.03
(the Max. frequency)
Setting range of P01.10: 0.00–50.00s
Setting range of P01.11: 0.0–100.0%
Setting range of P01.12: 0.00–50.00s
During the procedure of switching FWD/REV rotation,
set the threshold by P01.14, which is as the table below:
Output frequency
FWD
Starting
frequency
Setting range: 0.0–3600.0s
P01.09
P13.14
Constant
speed
DEC
P01.12
P0110
In running
Shift after the
Starting frequency
Shift after the
Zero frequency
REV
-32-
Function Parameters
Default
Modify
value
0.00Hz
0.00s
0.0%
0.00s
t
0.0s
T