Filling Liquid Chemicals Using The Turbofiller - Hardi NAVIGATOR Classic EAGLE 3000 Instruction Book

Hide thumbs Also See for NAVIGATOR Classic EAGLE 3000:
Table of Contents

Advertisement

5 - Operation

Filling Liquid Chemicals Using the TurboFiller

μ
ATTENTION! We advice to use the TurboFiller, when you fill chemicals on the sprayer.
1. Fill the MainTank at least 1/3 with water (unless otherwise stated
on the chemical container label).
2. Turn the handle of the suction SmartValve towards "MainTank".
3. Turn the pressure SmartValve towards "Pressure
draining/TurboFiller".
4. Close the agitation valve.
μ
ATTENTION! If filling water from an external tank, this can be
continued while doing the next steps.
DANGER! It is very important to ensure that the quick coupler lid
is correctly and completely fitted to the filling stud in its locked position, before turning pressure SmartValve to
"Pressure draining/TurboFiller". Failure to do so may cause risk of contamination and injury from quick coupler lid
being "shot" off when pressurized! If not possible to fit the lid completely, lubricate the rubber seal and the grip hooks.
5. Engage the pump and set PTO speed at max. 540 RPM or 1000 RPM (depending on pump model).
6. Open the TurboFiller lid. Measure the correct quantity of chemical and fill it into the hopper.
DANGER! Always wear face shield and other appropriate personal safety equipment, when filling chemicals.
μ
ATTENTION! The scale in the hopper can only be used, if the sprayer is parked on level ground! It is recommended to
use a measuring jug for best accuracy.
7. Engage the hopper transfer device by opening the TurboFiller
suction valve to transfer chemicals to the MainTank. The TurboFiller
suction valve must be open for at least 20 seconds after the
chemical is no longer visible in the hopper, in order to empty the
transfer hoses completely into the MainTank.
DANGER! If the TurboFiller and the transfer hoses are not
completely emptied, there is a risk of chemicals flowing back into
the hopper!
8. If the chemical container is empty, it can be rinsed by the "chemical
container cleaning device". Place the container over the multi-hole
nozzle and press the lever to activate container cleaning.
DANGER! In order to avoid spray liquid hitting the operator, do
not press the lever, unless the multi-hole nozzle is covered by a
container, as spray liquid may otherwise hit the operator!
μ
ATTENTION! The rinsing device uses spray liquid to rinse
containers for concentrated chemicals. Before disposal, always rinse the chemical containers with clean water several
times, until they are clean.
9. Flush the TurboFiller with clean water by shifting to suction from the RinseTank or from an external tank. The TurboFiller
suction valve must be open for at least 20 seconds after the rinse water is no longer visible in the hopper, in order to
empty the transfer hoses completely into the MainTank.
μ
ATTENTION! If the suction SmartValve is not shifted to suction from a clean water supply, the hopper rinsing device
uses spray liquid for rinsing the hopper! Cleaning the TurboFiller must always be done, when the spray job is ended,
and together with cleaning the entire sprayer. A cleaning after the last filling, and before spraying, does not ensure a
clean TurboFiller!
10. Close the TurboFiller suction valve, when the hopper has been rinsed. Close the lid.
98

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ranger eagle 2500

Table of Contents