Filling liquid chemicals by HARDI TurboFiller (optional)

1. Fill the main tank at least 1/3 with water (unless otherwise stated
on the chemical container label).
2. Turn the handle of the suction valve towards "suction from Main
tank". Turn pressure SmartValve towards "Pressure
draining/TurboFiller". Turn the AgitationValve towards "Agitation" if
required.
μ
ATTENTION! For increased suction from the TurboFiller the
AgitationValve can be kept closed.
DANGER! Before turning Pressure SmartValve to "Pressure
draining/TurboFiller" it is very important to be sure that the quick
coupler lid is correct and completely mounted to the filling stud into its locked position. Failure to do so may cause
risk of contamination and injury from quick coupler lid being "shot" off when pressurized! If not possible to mount lid
completely, lubricate the rubber seal and the grip hooks.
3. Engage the pump and set P.T.O. speed at 540 r/min or 1000 r/min (depending on pump model).
4. Open TurboFiller lid. Measure the correct quantity of chemical and fill it into the hopper.
DANGER! Always wear face shield and other appropriate personal safety equipment when filling chemicals.
μ
ATTENTION! The scale in the hopper can only be used if the sprayer is parked on level ground! It is recommended to
use a measuring jug for best accuracy.
5. Engage the hopper transfer device by opening the TurboFiller suction valve and the chemical is being transferred to
the main tank.
μ
ATTENTION! The hopper rinsing device is using spray liquid for rinsing the hopper for concentrated chemical!
Cleaning the TurboFiller must always be done when the spray job is ended and together with the entire sprayer - a
cleaning after the last filling and before spraying the last tankful does not ensure a clean TurboFiller!
6. If the chemical container is empty, it can be rinsed by the Chemical Container Cleaning device. Place the container
over the multi-hole nozzle and push the upper lever to the left of the TurboFiller.
DANGER! In order to avoid spray liquid hitting the operator, do not press lever unless the multi-hole nozzle is covered
by a container as spray liquid may otherwise hit the operator.
7. Close TurboFiller suction valve when the hopper has been rinsed.
8. Close the TurboFiller lid.
μ
ATTENTION! Rinsing device uses spray liquid to rinse containers for concentrated chemicals. Always rinse the che-
mical containers with clean water several times until they are clean before disposal.
9. If closed, turn the AgitationValve towards "Agitation".
10. When the spray liquid is well agitated, turn handle of the pressure
SmartValve towards "Spraying" position. Keep P.T.O. engaged so
the spray liquid is continuously agitated until it has been sprayed
on the crop.