T10FM
IMPORTANT
When closing the cover of the stator housing, make sure that the
internal connection cables are positioned in the grooves provided and
are not trapped.
7.4 Setting the pulse count
The number of pulses per revolution of the rotor in the speed module option
can be adjusted by means of DIP switches S1...S4.
Fig. 7.6: Switches for setting the pulse count
Setting the pulse count
1. Remove the stator cover.
2. Use switches S1 ... S4 as per Tab. 7.1 to set the required pulse count.
Pulses/revolution
Switch settings for the pulse count (
Tab. 7.1:
1)
Factory setting
A0894-5.2 en
Switches S1...S4
1)
720
360
S4
S1
180
90
60
¢ switch lever)
35
30
15
HBM