IGNITION COIL
SERVICING

Ignition Coil Removal

Remove spark plug lead from ignition coil.
Disconnect ignition coil electrical connector.
Remove two ignition coil retaining screws.
Do not lose the rubber washers between coil and
bracket.
1. Screws
Ignition Coil Bracket Removal
Remove spark plug lead ground screw.
Remove injector screws and bracket.
1. Injector screws
IMPORTANT:
All injectors must be installed in
the correct cylinder by serial number. If removed,
mark fuel injectors to show cylinder locations.
Ignition Coil Bracket Installation
Install injector screws through bracket.
Refer to Fuel Injector Service on p. 150 for
proper injector installation procedure.
1
1
1. Injector screws
Install spark plug leads with ground screw. Tighten
screw securely.

Ignition Coil Installation

Install one rubber washer on each screw. Install
screw through ignition coil.
007187
Install remaining rubber washers on screws
between coil and bracket.
1
1. Rubber washers
Install coil with washers on bracket.
007188
Tighten screws to a torque of 60 to 84 in. lb. (7 to
9.5 N·m).
Install spark plug lead on ignition coil.
Connect ignition coil electrical connector.
ELECTRICAL AND IGNITION

IGNITION COIL SERVICING

007189
6
1
007186