Ignition Primary Circuit Resistance Test; Ignition Coil Tests - BRP E250DHLSCS Service Manual

Evinrude e-tec series 250, 300 hp 90 v6 (3.4l)
Table of Contents

Advertisement

Ignition Primary Circuit
Resistance Test
Disconnect the battery cables at the battery.
Calibrate ohmmeter to low ohms scale.
With key switch OFF, remove the EMM J1-B con-
nector and measure resistance of each primary
circuit. Note resistance reading between each pri-
mary wire and ground. Refer to engine wiring dia-
gram.
Ignition Coil Primary Circuit Resistance
0.090 ± 0.005 Ω.
A reading of less than 2 ohms is
IMPORTANT:
acceptable. Make sure meter is calibrated to read
1 ohm or less.
3
1. J1-B connector
2. Red meter lead, with pin adapter
3. Black meter lead to ground
Results:
Primary circuit (complete circuit) resistance read-
ing is higher than 2 Ω:
Repair primary circuit wiring or coil grounds as
needed and retest.
Replace faulty coils or wiring.
Primary circuit resistance reading less than 2 Ω or
within specification and EMM ignition output volt-
age is 130 V or higher:
Refer to Ignition Coil Tests on p. 119. Repair
high tension spark plug lead or replace ignition
coil and/or high tension spark plug lead assem-
bly.

Ignition Coil Tests

Connect a digital multimeter between coil primary
terminal and clean engine ground.
Ignition Coil Primary Resistance
0.090 ± .005 Ω @ 77°F (25°C)
IMPORTANT:
acceptable. Make sure meter is calibrated to read
1 ohm or less.
1
2
Connect meter between coil secondary terminal
and coil primary terminal.
Ignition Coil Secondary Resistance
301 ± 14 Ω @ 77°F (25°C)
004328
SYSTEM ANALYSIS
IGNITION OUTPUT TESTS
A reading of less than 2 ohms is
6
000741
000742
119