Exhaust Housing Assembly - V4 Models - BRP EVINRUDE E-TEC 115 HP 2011 Service Manual

Table of Contents

Advertisement

MIDSECTION
EXHAUST HOUSING SERVICE
Cleaning Solvent. Apply Gel-Seal II sealant to the
adapter flange of the exhaust housing.
Place the adapter/inner exhaust housing into the
exhaust housing. Guide the water tube through
the hole in the outer housing.
Apply Triple-Guard grease to threads of adapter
retaining screws. Tighten two forward screws to a
torque of 216 to 240 in. lbs. (24.5 to 27 N·m) and
rear screw to a torque of 60 to 84 in. lbs. (7 to 9.5
N·m).
1
1. Adapter retaining screws
246
Exhaust Housing Assembly –
V4 Models
Install the collar on shaft.
Use a 0.030 in. (0.762 mm) feeler gauge to set the
gap between the collar and exhaust housing as
shown.
13692
1. Set gap to 0.030 in. (0.762 mm)
Tighten screw to a torque of 60 to 84 in. lb. (18 to
20 N·m).
1
1
1. Screw
005205
1
007192
007185

Advertisement

Table of Contents
loading