BRP EVINRUDE E-TEC 115 HP 2011 Service Manual page 13

Table of Contents

Advertisement

HP
Minimum Battery
Requirements
Alternator
Tachometer Setting
Charging Isolator
Engine Fuse
Thermostat
Maximum Temperature
Water pressure
Type
Firing Order
Ignition Features
RPM Limit
Crankshaft Position Sensor Air
Gap
Spark Plug
Gear Ratio
Lubricant
Capacity
Shift Rod Height
Shift Cable Stroke
Lubrication
Fluid Capacity
Trim Range
Tilt Range
115, 130
675 CCA (845 MCA); or
750 CCA (940 MCA) below 32°F (0°C)
(Use a 107 amp-hr battery for extreme applications.)
Dual Voltage 50 Amp with Voltage Regulator and Battery Isolation. Refer to Predeliv-
ery and Installation Guide for multiple battery applications.
Integral, Terminal on Engine Harness
230°F (110°C) Below 3000 RPM and 194°F (90°C) Above 3000 RPM
V4: 21 to 23 psi @ 5000 RPM
V6: 23 to 25 psi @ 5000 RPM
1-2-3-4
Refer to Emission Control Information Label
Champion
QC10WEP @ 0.028 ± 0.003 in. (0.76 mm)
Refer to Emission Control Information Label
V4 "S2" Type Gearcase: 13:26 (.500) (2:1)
V4 "O" Type Gearcase: 12:27 (.444) (2.25:1)
V6 "O" Type Gearcase: 14:26 (.538) (1.86:1)
V6 "M2" Type Gearcase: 13:24 (.542) (1.85:1)
V6 "L2" Type Gearcase: 14:26 (.538) (1.86:1)
Refer to GEARCASE TYPES on p. 263
HPF XR Gearcase Lubricant
"S2" Type Gearcase: 31.6 fl. oz. (935 ml)
V4 "O" Type Gearcase: 32.8 fl. oz. (970 ml)
V6 "O" Type Gearcase: 33.1 fl. oz. (980 ml)
"M2" Type Gearcase: 38.9 fl. oz. (1150 ml)
"M2" Type – Counter Rotation: 35.8 fl. oz. (1060 ml)
"L2" Type Gearcase: 32.5 fl. oz. (960 ml)
20 in. (L) Models: 20.945 (532 mm) ± one-half turn
25 in. (X) Models: 25.945 (659 mm) ± one-half turn
1.125 to 1.330 in. (28.6 to 33.8 mm) measured between NEUTRAL and FORWARD
(Single Piston style): Evinrude/Johnson Biodegradeable TNT Fluid
(Three Piston style): Evinrude/Johnson Power Trim/Tilt & Power Steering Fluid or GM
Dextron
II Automatic Transmission Fluid
REFERENCE INFORMATION
SERVICE SPECIFICATIONS
150, 175, 200
6 pulse (12 pole)
P/N 967545 – 10 A
143°F (62°C)
Capacitor Discharge
1-2-3-4-5-6
EMM Controlled
6250
Fixed
21 fl. oz. (622ml)
0° to 21°
22° to 75°
1
11

Advertisement

Table of Contents
loading